CoChat

Pulmonary function in young and older athletes and untrained men

Hagberg, J. M., Yerg, J. E., Seals, D. R. · 1988 · Journal of Applied Physiology

The DOI matches its Crossref record.

Abstract

This study compared the lung volumes and pulmonary functions of older endurance-trained athletes with those of healthy sedentary age-matched controls, young athletes, and young untrained men to determine whether training affects the age-associated changes in these variables. Despite large differences in maximal 02 consumption (VO2max), the older athletes and their sedentary peers had similar values for all pulmonary variables when expressed as absolute values. However, because the older athletes were shorter than the older sedentary men, their vital capacity, total lung capacity (TLC), and forced expiratory volume in 1 s were significantly larger than those of the older sedentary men when normalized for age and height; the average values for maximal voluntary ventilation and residual volume (RV) were also larger in the older athletes when normalized for age and height, but the differences were not significant. The young trained and untrained men did not differ in any of these measures. TLC was the only pulmonary variable that was the same in the young and older men; RV and the RV-to-TLC ratio were larger, whereas all other pulmonary function and volume measures were lower in the older men compared with the younger men. The older athletes were the only group whose lung volumes and pulmonary function measures were all, except for RV, substantially greater than expected based on their age and height. Thus prolonged strenuous endurance training in these older highly trained endurance athletes appears to have altered the decline in pulmonary function and volumes associated with aging.

Overview

Integrity signals

Registry

Crossref · 10.1152/jappl.1988.65.1.101

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Citations

Cites

Still being checked.

Cited by

See all 117

Metadata

Authors
Hagberg, J. M., Yerg, J. E., & Seals, D. R.
Affiliations
Washington University in St. Louis (US)
Venue
Journal of Applied Physiology
Published
1988-07-01
Volume
65
Issue
1
Pages
101-105
ISSN
  • 0161-7567 (ISSN-L)
  • 8750-7587
  • 1522-1601
OpenAlex
W2140263507
Cited by
115
References
0
Citations by year
2026: 3 · 2025: 3 · 2024: 3 · 2023: 4 · 2022: 5 · 2021: 4 · 2020: 2 · 2019: 4 · 2018: 3 · 2017: 5 · 2016: 8 · 2015: 5 · 2014: 4 · 2013: 6 · 2012: 8
FWCI
0.55
Type
journal article
Language
en
Open access
closed
Locations
  • Journal of Applied Physiology (publishedVersion)
  • PubMed (publishedVersion)
Funders
National Institute on Aging (AG-05294, AG-03038)
Topics
  • Health Sciences › Medicine › Physiology (medical) › Cardiovascular and exercise physiology
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Effects of Exercise
  • Health Sciences › Medicine › Orthopedics and Sports Medicine › Sports Performance and Training
Keywords
lung function, aging, endurance training, athletes, lung volume, vital capacity, total lung capacity, residual volume, VO2max, age-related lung function decline, maximal voluntary ventilation
MeSH terms
Adult, Aging, Forced Expiratory Volume, Humans, Lung, Male, Middle Aged, Oxygen Consumption, Physical Endurance, Sports, Total Lung Capacity, Vital Capacity

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Pulmonary function in young and older athletes and untrained men. https://app.cochat.ai/papers/10.1152/jappl.1988.65.1.101
The paper
Hagberg, J. M., Yerg, J. E., & Seals, D. R. (1988). Pulmonary function in young and older athletes and untrained men. Journal of Applied Physiology. https://doi.org/10.1152/jappl.1988.65.1.101

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.