The DOI matches its Crossref record.
Cutaneous laser-Doppler flowmetry: influence of underlying muscle blood flow
Abstract
To find whether the measurement of skin blood flow (SkBF) by laser-Doppler flowmetry (LDF) is influenced by blood flow to underlying skeletal muscle, five subjects performed mild forearm exercise to induce a metabolic hyperemia in muscle in both forearms. This exercise consisted of alternative opening and closing of both hands at a frequency of approximately 1/s for a duration of 3 min. This exercise was performed twice by each subject. Forearm blood flow (FBF) by plethysmography increased from 2.64 +/- 0.49 (rest) to 31.11 +/- 9.95 ml.100 ml-1.min-1 (immediately after exercise) (P less than 0.001). No statistically significant postexercise increase was observed in LDF measured on the dorsal (110 +/- 21 to 105 +/- 21 mV) or ventral surface (266 +/- 113 to 246 +/- 77 mV) of the forearm. LDF measured from the chest also showed no significant change, indicating that the exercise was too mild to have reflex effects on SkBF. Moreover, the slope of the logarithmic linear regression and the half-time for recovery during the postexercise period for FBF were not reflected in LDF measurements from any of the three sites. We conclude that LDF measured from the skin surface is not influenced by blood flow to underlying skeletal muscle.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Skin blood flow in adult human thermoregulation: How it works, when it does not, and why
Charkoudian, N. (2003) · Mayo Clinic Proceedings · doi:10.4065/78.5.603 · Cited by 1,041
Role of nitric oxide in the vascular effects of local warming of the skin in humans
Kellogg, D. L., Liu, Y., Kosiba, I. F., & O’Donnell, D. (1999) · Journal of Applied Physiology · doi:10.1152/jappl.1999.86.4.1185 · Cited by 463
Self-citationCutaneous Vasodilator and Vasoconstrictor Mechanisms in Temperature Regulation
Johnson, J. M., Minson, C. T., & Kellogg, D. L. (2014) · Comprehensive Physiology · doi:10.1002/cphy.c130015 · Cited by 414
Self-citationNitric oxide and cutaneous active vasodilation during heat stress in humans
Kellogg, D. L., Crandall, C. G., Liu, Y., Charkoudian, N., & Johnson, J. M. (1998) · Journal of Applied Physiology · doi:10.1152/jappl.1998.85.3.824 · Cited by 312
Self-citationEffect of acute sleep deprivation on vascular function in healthy subjects
Sauvet, F., Leftheriotis, G., Gomez-Merino, D., Langrume, C., Drogou, C., Van Beers, P., Bourrilhon, C., Florence, G., & Chennaoui, M. (2010) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00851.2009 · Cited by 268
Metadata
- Authors
- Saumet, J. L., Kellogg, D. L., Taylor, W. F., & Johnson, J. M.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 1988-07-01
- Volume
- 65
- Issue
- 1
- Pages
- 478-481
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2259110695
- Cited by
- 164
- References
- 0
- FWCI
- 3.58
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Cutaneous laser-Doppler flowmetry: influence of underlying muscle blood flow. https://app.cochat.ai/papers/10.1152/jappl.1988.65.1.478
- The paper
- Saumet, J. L., Kellogg, D. L., Taylor, W. F., & Johnson, J. M. (1988). Cutaneous laser-Doppler flowmetry: influence of underlying muscle blood flow. Journal of Applied Physiology. https://doi.org/10.1152/jappl.1988.65.1.478
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.