Comparison of doubly labeled water with respirometry at low- and high-activity levels
The DOI matches its Crossref record.
Abstract
In previous studies the doubly labeled water method for measuring energy expenditure in free-living humans has been validated against respirometry under sedentary conditions. In the present investigation, energy expenditure is measured simultaneously with doubly labeled water and respirometry at low- and high-activity levels. Over 6 days, five subjects were measured doing mainly sedentary activities like desk work; their average daily metabolic rate was 1.40 +/- 0.09 (SD) times sleeping metabolic rate. Four subjects were measured twice over 3.5 days, including 2 days with heavy bicycle ergometer work, resulting in an average daily metabolic rate of 2.61 +/- 0.25 (SD) times sleeping metabolic rate. At the low-activity level, energy expenditures from the doubly labeled water method were on the average 1.4 +/- 3.9% (SD) larger than those from respirometry. At the high-activity level, the doubly labeled water method yielded values that were 1.0 +/- 7.0% (SD) lower than those from respirometry. Results demonstrate the utility of the doubly labeled water method for the determination of energy expenditure in the range of activity levels in daily life.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Markers of the Validity of Reported Energy Intake
Livingstone, M. B. E., & Black, A. E. (2003) · The Journal of Nutrition · doi:10.1093/jn/133.3.895s · Cited by 1,081
Accuracy of Armband Monitors for Measuring Daily Energy Expenditure in Healthy Adults
JOHANNSEN, D. L., CALABRO, M. A., STEWART, J., FRANKE, W., ROOD, J. C., & WELK, G. J. (2010) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3181e0b3ff · Cited by 424
Indirect calorimetry: methodological and interpretative problems
Simonson, D. C., & DeFronzo, R. A. (1990) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.1990.258.3.e399 · Cited by 376
Schuit, A. J., Schouten, E. G., Westerterp, K. R., & Saris, W. H. M. (1997) · Journal of Clinical Epidemiology · doi:10.1016/s0895-4356(97)00010-3 · Cited by 337
Self-citationRelative dilution spaces of 2H- and 18O-labeled water in humans
Racette, S. B., Schoeller, D. A., Luke, A. H., Shay, K., Hnilicka, J., & Kushner, R. F. (1994) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.1994.267.4.e585 · Cited by 316
Metadata
- Authors
- Westerterp, K. R., Brouns, F., Saris, W. H., & ten Hoor, F.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 1988-07-01
- Volume
- 65
- Issue
- 1
- Pages
- 53-56
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2100040029
- Cited by
- 102
- References
- 0
- FWCI
- 3.36
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Comparison of doubly labeled water with respirometry at low- and high-activity levels. https://app.cochat.ai/papers/10.1152/jappl.1988.65.1.53
- The paper
- Westerterp, K. R., Brouns, F., Saris, W. H., & ten Hoor, F. (1988). Comparison of doubly labeled water with respirometry at low- and high-activity levels. Journal of Applied Physiology. https://doi.org/10.1152/jappl.1988.65.1.53
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.