Effect of airway impedance on CO2 retention and respiratory muscle activity during NREM sleep
The DOI matches its Crossref record.
Abstract
We hypothesized that a sleep-induced increase in mechanical impedance contributes to CO2 retention and respiratory muscle recruitment during non-rapid-eye-movement (NREM) sleep. The effect NREM sleep on respiratory muscle activity and CO2 retention was measured in healthy subjects who increased maximum total pulmonary resistance (RLmax, 1-81 cmH2O.l-1.s) from awake to NREM sleep. We determined the effects of this sleep-induced increase in airway impedance by steady-state inhalation of a reduced-density gas mixture (79% He-21% O2, He-O2). Both arterialized blood PCO2 (PaCO2) and end-tidal PCO2 (PETCO2) were measured. Inspiratory (EMGinsp) and expiratory (EMGexp) respiratory muscle electromyogram activity was measured. NREM sleep caused 1) RLmax to increase (7 +/- 3 vs. 39 +/- 28 cmH2O.l-1.s), 2) PaCO2 and/or PETCO2 to increase in all subjects (40 +/- 2 vs. 44 +/- 3 Torr), and 3) EMGinsp to increase in 8 of 9 subjects and EMGexp to increase in 9 of 17 subjects. Compared with steady-state air breathing during NREM sleep, steady-state He-O2 breathing 1) reduced RLmax by 38%, 2) decreased PaCO2 and PETCO2 by 2 Torr, and 3) decreased both EMGinsp (-20%) and EMGexp (-54%). We concluded that the sleep-induced increase in upper airway resistance accompanied by the absence of immediate load compensation is an important determinant of CO2 retention, which, in turn, may cause augmentation of inspiratory and expiratory muscle activity above waking levels during NREM sleep.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Control of sleep and wakefulness
Brown, R. E., Basheer, R., McKenna, J. T., Strecker, R. E., & McCarley, R. W. (2012) · Physiological Reviews · doi:10.1152/physrev.00032.2011 · Cited by 1,477
Eckert, D. J., Jordan, A. S., Merchia, P., & Malhotra, A. (2007) · Chest · doi:10.1378/chest.06.2287 · Cited by 559
Effect of Weight Loss on Upper Airway Collapsibility in Obstructive Sleep Apnea
Schwartz, A. R., Gold, A. R., Schubert, N., Stryzak, A., Wise, R. A., Permutt, S., & Smith, P. L. (1991) · American Review of Respiratory Disease · doi:10.1164/ajrccm/144.3_pt_1.494 · Cited by 477
Definition, discrimination, diagnosis and treatment of central breathing disturbances during sleep
Randerath, W., Verbraecken, J., Andreas, S., Arzt, M., Bloch, K. E., Brack, T., Buyse, B., De Backer, W., Eckert, D. J., Grote, L., et al. (2017) · European Respiratory Journal · doi:10.1183/13993003.00959-2016 · Cited by 354
Iscoe, S. (1998) · Progress in Neurobiology · doi:10.1016/s0301-0082(98)00046-x · Cited by 218
Eckert, D. J., Malhotra, A., & Jordan, A. S. (2009) · Progress in Cardiovascular Diseases · doi:10.1016/j.pcad.2008.02.003 · Cited by 173
“However, over time, if stable sleep is achieved, the reduction in ventilation at sleep onset is coupled with a gradual rise in PaCO2 (~38 mm Hg), and a new sleep-specific carbon dioxide set point (~45 mm Hg) is established.(57) The loss of behavioral influences that strongly oppose breathing cessation duringwakefulnes…”
BackgroundSleep-Disordered Breathing: Access Is the Issue
Pack, A. I. (2004) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.2401008 · Cited by 163
Upper airway muscle responsiveness to rising P co2during NREM sleep
Pillar, G., Malhotra, A., Fogel, R. B., Beauregard, J., Slamowitz, D. I., Shea, S. A., & White, D. P. (2000) · Journal of Applied Physiology · doi:10.1152/jappl.2000.89.4.1275 · Cited by 76
Metadata
- Authors
- Skatrud, J. B., Dempsey, J. A., Badr, S., & Begle, R. L.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 1988-10-01
- Volume
- 65
- Issue
- 4
- Pages
- 1676-1685
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2173456905
- Cited by
- 90
- References
- 0
- FWCI
- 1.96
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.