CoChat

Changes in size and compliance of the calf after 30 days of simulated microgravity

Convertino, V. A., Doerr, D. F., Stein, S. L. · 1989 · Journal of Applied Physiology
Cited by 105

The DOI matches its Crossref record.

Abstract

Increased leg venous compliance may contribute to postflight orthostatic intolerance in astronauts. We reported that leg compliance was inversely related to the size of the muscle compartment. The purpose of this study was to test the hypothesis that reduced muscle compartment after long-duration exposure to microgravity would cause increased leg compliance. Eight men, 31–45 yr old, were measured for vascular compliance of the calf and serial circumferences of the calf before and after 30 days of continuous 6 degrees head-down bed rest. Cross-sectional areas (CSA) of muscle, fat, and bone compartments in the calf were determined before and after bed rest by computed tomography. From before to after bed rest, calculated calf volume (cm3) decreased (P less than 0.05) from 1,682 +/- 83 to 1,516 +/- 76. Calf muscle compartment CSA (cm2) also decreased (P less than 0.05) from 74.2 +/- 3.6 to 70.6 +/- 3.4; calf compliance (ml.100 ml-1.mmHg-1.100) increased (P less than 0.05) from 3.9 +/- .7 to 4.9 +/- .5. The percent change in calf compliance after bed rest was significantly correlated with changes in calf muscle compartment CSA (r = 0.72, P less than 0.05). The increased leg compliance observed after exposure to simulated microgravity can be partially explained by reduced muscle compartment. Countermeasures designed to minimize muscle atrophy in the lower extremities may be effective in ameliorating increased venous compliance and orthostatic intolerance after spaceflight.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1152/jappl.1989.66.3.1509

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 105

Metadata

Authors
Convertino, V. A., Doerr, D. F., & Stein, S. L.
Venue
Journal of Applied Physiology
Published
1989-03-01
Volume
66
Issue
3
Pages
1509-1512
ISSN
  • 0161-7567 (ISSN-L)
  • 8750-7587
  • 1522-1601
OpenAlex
W2160004239
Cited by
105
References
0
FWCI
0.72
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Changes in size and compliance of the calf after 30 days of simulated microgravity. https://app.cochat.ai/papers/10.1152/jappl.1989.66.3.1509
The paper
Convertino, V. A., Doerr, D. F., & Stein, S. L. (1989). Changes in size and compliance of the calf after 30 days of simulated microgravity. Journal of Applied Physiology. https://doi.org/10.1152/jappl.1989.66.3.1509

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.