CoChat

Accuracy of pulse oximetry to estimate HbO2 fraction of total Hb during exercise

Powers, S. K., Dodd, S., Freeman, J., Ayers, G. D., Samson, H., McKnight, T. · 1989 · Journal of Applied Physiology
Cited by 53

The DOI matches its Crossref record.

Abstract

The accuracy of two pulse oximeters (Ohmeda 3700 and Biox IIa) was evaluated during cycle ergometer incremental exercise in 10 healthy subjects. The exercise protocol began at 30 W with the power output being increased 15 W.min-1 until volitional fatigue. Ear and finger probe pulse oximetry measurements of available hemoglobin (%Spo2) were compared with arterial oxyhemoglobin fraction of total hemoglobin (%HbO2) measured directly from arterial blood samples using a CO-oximeter. To provide a wide range of %HbO2 values, four subjects exercised under hypoxic conditions [inspired partial pressure of O2 (PIo2) = 107 Torr], while the remaining six subjects exercised under normoxic conditions (PIo2 = 150 Torr). Because carboxyhemoglobin (HbCO) or methemoglobin (MetHb) is not measured by pulse oximeters, %HbO2 was corrected for HbCO and MetHb and expressed as percent arterial O2 saturation of available Hb (%Sao2). Small and insignificant differences (P greater than 0.05) existed between SpO2 (all 3 instruments) and %SaO2 at the lowest work rate and the highest power output achieved. Regression analyses of %SpO2 vs. %SaO2 produced correlation coefficients of r = 0.82 [standard error of the estimate [(SEE) = 1.79], r = 0.89 (SEE = 1.48), and r = 0.93 (SEE = 1.14) for the Biox IIa, Ohmeda 3700 (ear), and the Ohmeda 3700 (finger) pulse oximeters, respectively. We conclude that pulse oximetry, within the above limits of accuracy, is useful in estimating %SaO2 during exercise in healthy subjects.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1152/jappl.1989.67.1.300

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 53

Metadata

Authors
Powers, S. K., Dodd, S., Freeman, J., Ayers, G. D., Samson, H., & McKnight, T.
Venue
Journal of Applied Physiology
Published
1989-07-01
Volume
67
Issue
1
Pages
300-304
ISSN
  • 0161-7567 (ISSN-L)
  • 8750-7587
  • 1522-1601
OpenAlex
W1922986649
Cited by
53
References
0
FWCI
2.50
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Accuracy of pulse oximetry to estimate HbO2 fraction of total Hb during exercise. https://app.cochat.ai/papers/10.1152/jappl.1989.67.1.300
The paper
Powers, S. K., Dodd, S., Freeman, J., Ayers, G. D., Samson, H., & McKnight, T. (1989). Accuracy of pulse oximetry to estimate HbO2 fraction of total Hb during exercise. Journal of Applied Physiology. https://doi.org/10.1152/jappl.1989.67.1.300

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.