Meta-analysis of arterial oxygen saturation monitoring by pulse oximetry in adults

Jensen, Louise A., Onyskiw, Judee E., Prasad, N.G.N.·1998·Heart & Lung

Abstract

Objective The purposes of the study were to: (1) describe the aggregate strength of the relationship of arterial oxygen saturation as measured by pulse oximetry with the standard of arterial blood gas analysis as measured by co-oximetry, (2) examine how various factors affect this relationship, and (3) describe an aggregate estimate of the bias and precision between oxygen saturation as measured by pulse oximetry and the standard in vitro measures.Design A meta-analysis was conducted.Sample Seventy-four studies from 1976 to 1994 met the inclusion criteria of: (1) adult study population, (2) quantitative analysis of empirical data, and (3) bivariate correlations or bias and precision estimates between pulse oximeter and co-oximeter values.Results There were a total of 169 oximeter trials on 41 oximeter models from 25 different manufacturers. Studies were conducted in various settings with a variety of subjects, with most being healthy adult volunteers. The weighted mean r, based on 39 studies (62 oximeter trials) for which the r statistic and number of data points were available, was 0.895 (var [r] = 0.014). Based on 23 studies (82 oximeter trials) for which bias and precision estimates and number of data points were available, the mean absolute bias and precision were 1.999 and 0.233, respectively. Several factors were found to affect the accuracy of pulse oximetry.Conclusion Pulse oximeters were found to be accurate within 2% (+/- 1 SD) or 5% (+/- 2 SD) of in vitro oximetry in the range of 70% to 100% Sao2. In comparing ear and finger probes, readings from finger probes were more accurate. Pulse oximeters may fail to record accurately the true Sao2 during severe or rapid desaturation, hypotension, hypothermia, dyshemoglobinemia, and low perfusion states.

Integrity signals

Registry

Crossref · 10.1016/s0147-9563(98)90086-3

Cites

198 of 198 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Jensen, L. A., Onyskiw, J. E., & Prasad, N. G. N.
Affiliations
University of Alberta (CA)
Venue
Heart & Lung
Publisher
Elsevier BV
Published
1998-11
Volume
27
Issue
6
Pages
387-408
ISSN
0147-9563 (ISSN-L)
OpenAlex
W2112793666
Cited by
243
References
198
Citations by year
2026: 6 · 2025: 10 · 2024: 8 · 2023: 8 · 2022: 11 · 2021: 12 · 2020: 9 · 2019: 12 · 2018: 9 · 2017: 9 · 2016: 6 · 2015: 13 · 2014: 7 · 2013: 9 · 2012: 12
FWCI
1.34
Type
journal article
Language
en
Open access
closed
Locations
  • Heart & Lung (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
  • Health Sciences › Medicine › Surgery › Hemodynamic Monitoring and Therapy
  • Physical Sciences › Chemical Engineering › Bioengineering › Analytical Chemistry and Sensors
Keywords
pulse oximetry, arterial oxygen saturation, co-oximetry, arterial blood gases, measurement accuracy, bias and precision, finger probe, desaturation, hypotension, hypothermia, low perfusion, adults
MeSH terms
Adult, Clinical Trials as Topic, Female, Humans, Male, Monitoring, Physiologic, Oximetry, Oxygen, Oxygen Consumption, Reference Values, Sensitivity and Specificity, Reproducibility of Results

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review