Body composition and skin temperature variation
The DOI matches its Crossref record.
Abstract
Temperature variations near four common torso skin temperature sites were measured on 17 lightly clad subjects exposed to ambient temperatures of 28, 23, and 18 degrees C. Although variations in skin temperature exceeding 7 degrees C over a distance of 5 cm were observed on individuals, the mean magnitude of these variations was 2-3 degrees C under the coolest condition and less at the warmer temperatures. There was no correlation between the temperature variation and skinfold thickness at a site or with estimations of whole body fat content. These findings imply that errors in mean skin temperature measurement could arise from probe mislocation and/or subcutaneous fat distribution and that the problem becomes more acute with increasing cold stress. However, the magnitudes of these errors cannot be easily predicted from common anthropometric measurements.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Considerations for the measurement of core, skin and mean body temperatures
Taylor, N. A. S., Tipton, M. J., & Kenny, G. P. (2014) · Journal of Thermal Biology · doi:10.1016/j.jtherbio.2014.10.006 · Cited by 420
Stone, G. J., Young, W. L., Smith, C. R., Solomon, R. A., Wald, A., Ostapkovich, N., & Shrebnick, D. B. (1995) · Anesthesiology · doi:10.1097/00000542-199502000-00004 · Cited by 260
Reproducibility of infrared thermography measurements in healthy individuals
Zaproudina, N., Varmavuo, V., Airaksinen, O., & Närhi, M. (2008) · Physiological Measurement · doi:10.1088/0967-3334/29/4/007 · Cited by 246
“The skin temperature recorded by the IRT scan is more stable in the trunk, but in the extremities the variation is great and seems to depend on several endogenous factors such as the activity of the sympathetic nervous system as well as on the environmental temperature (Frim et al 1990).”
BackgroundAdiposity and human regional body temperature
Savastano, D. M., Gorbach, A. M., Eden, H. S., Brady, S. M., Reynolds, J. C., & Yanovski, J. A. (2009) · The American Journal of Clinical Nutrition · doi:10.3945/ajcn.2009.27567 · Cited by 223
“Infrared thermography showed local heterogeneities in abdominal skin temperatures and enabled placement of dermal thermistors on warm or cool areas of the skin more reliably than by depending on standard torso sites (24).”
BackgroundMethodEvaluation of mean skin temperature formulas by infrared thermography
Choi, J. K., Miki, K., Sagawa, S., & Shiraki, K. (1997) · International Journal of Biometeorology · doi:10.1007/s004840050056 · Cited by 189
Greer, R. J., Cohn, L. A., Dodam, J. R., Wagner-Mann, C. C., & Mann, F. A. (2007) · Journal of the American Veterinary Medical Association · doi:10.2460/javma.230.12.1841 · Cited by 101
Metadata
- Authors
- Frim, J., Livingstone, S. D., Reed, L. D., Nolan, R. W., & Limmer, R. E.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 1990-02-01
- Volume
- 68
- Issue
- 2
- Pages
- 540-543
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2136004370
- Cited by
- 53
- References
- 0
- FWCI
- 0.00
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.