The DOI matches its Crossref record.
Determination of esophageal probe insertion length based on standing and sitting height
Abstract
The present study derives simple formulas for the prediction of optimal insertion length of an esophageal temperature-sensitive probe from the measurements of either standing or sitting height. The formulas assume that the optimal site for an esophageal temperature probe is in the region of the esophagus bounded by the left ventricle and aorta, corresponding to the level of the eighth and ninth thoracic vertebrae (T8 and T9, respectively). An esophageal probe was constructed of polyethylene tubing containing 1-cm segments of alternating radiopaque and nonradiopaque tubing in the distal 20 cm of the probe. The probe was inserted through a nostril into the esophagus of 20 subjects (12 males and 8 females) of various heights (range 163-194.6 cm) and weights (range 52.2-100.8 kg), and lateral chest radiograms were obtained for determination of the insertion length of the probe (L) required to situate the probe in the retrocardiac esophagus. Analysis of the radiograms demonstrated that, at the level of the intervertebral disc between T8 and T9, the probe was below the tracheal bifurcation and close to the left ventricle. The distance from the nasal flare to this level showed a good correlation with the subject's stretched stature (r2 = 0.71) and sitting height (r2 = 0.86). The following equations were derived to predict the placement of the esophageal probe at the T8/T9 level based on standing height: L (CM) = 0.228 x (standing height) - 0.194, and sitting height: L (cm) = 0.479 x (sitting height) - 4.44.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Heat Flow and Distribution during Induction of General Anesthesia
Matsukawa, T., Sessler, D. I., Sessler, A. M., Schroeder, M., Ozaki, M., Kurz, A., & Cheng, C. (1995) · Anesthesiology · doi:10.1097/00000542-199503000-00008 · Cited by 528
Considerations for the measurement of core, skin and mean body temperatures
Taylor, N. A. S., Tipton, M. J., & Kenny, G. P. (2014) · Journal of Thermal Biology · doi:10.1016/j.jtherbio.2014.10.006 · Cited by 420
Heat Flow and Distribution during Epidural Anesthesia
Matsukawa, T., Sessler, D. I., Christensen, R., Ozaki, M., & Schroeder, M. (1995) · Anesthesiology · doi:10.1097/00000542-199511000-00008 · Cited by 290
Hyperthermia: a failure of the motor cortex and the muscle
Todd, G., Butler, J. E., Taylor, J. L., & Gandevia, S. C. (2005) · The Journal of Physiology · doi:10.1113/jphysiol.2004.077115 · Cited by 260
Core Temperature Measurement—Principles of Correct Measurement, Problems, and Complications
Hymczak, H., Gołąb, A., Mendrala, K., Plicner, D., Darocha, T., Podsiadło, P., Hudziak, D., Gocoł, R., & Kosiński, S. (2021) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph182010606 · Cited by 161
Metadata
- Authors
- Mekjavic, I. B., & Rempel, M. E.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 1990-07-01
- Volume
- 69
- Issue
- 1
- Pages
- 376-379
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2122081798
- Cited by
- 249
- References
- 0
- FWCI
- 1.97
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Determination of esophageal probe insertion length based on standing and sitting height. https://app.cochat.ai/papers/10.1152/jappl.1990.69.1.376
- The paper
- Mekjavic, I. B., & Rempel, M. E. (1990). Determination of esophageal probe insertion length based on standing and sitting height. Journal of Applied Physiology. https://doi.org/10.1152/jappl.1990.69.1.376
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.