The DOI matches its Crossref record.
Effect of mild-to-moderate airflow limitation on exercise capacity
Abstract
To determine the effect of mild-to-moderate airflow limitation on exercise tolerance and end-expiratory lung volume (EELV), we studied 9 control subjects with normal pulmonary function [forced expired volume in 1 s (FEV1) 105% pred; % of forced vital capacity expired in 1 s (FEV1/FVC%) 81] and 12 patients with mild-to-moderate airflow limitation (FEV1 72% pred; FEV1/FVC % 58) during progressive cycle ergometry. Maximal exercise capacity was reduced in patients [69% of pred maximal O2 uptake (VO2max)] compared with controls (104% pred VO2max, P less than 0.01); however, maximal expired minute ventilation-to-maximum voluntary ventilation ratio and maximal heart rate were not significantly different between controls and patients. Overall, there was a close relationship between VO2max and FEV1 (r2 = 0.62). Resting EELV was similar between controls and patients [53% of total lung capacity (TLC)], but at maximal exercise the controls decreased EELV to 45% of TLC (P less than 0.01), whereas the patients increased EELV to 58% of TLC (P less than 0.05). Overall, EELV was significantly correlated to both VO2max (r = -0.71, P less than 0.001) and FEV1 (r = -0.68, P less than 0.001). This relationship suggests a ventilatory influence on exercise capacity; however, the increased EELV and associated pleural pressures could influence cardiovascular function during exercise. We suggest that the increase in EELV should be considered a response reflective of the effect of airflow limitation on the ventilatory response to exercise.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Miller, M. R., Hankinson, J., Brusasco, V., Burgos, F., Casaburi, R., Coates, A., Crapo, R., Enright, P., van der Grinten, C. P. M., Gustafsson, P., et al. (2005) · European Respiratory Journal · doi:10.1183/09031936.05.00034805 · Cited by 15,627
Interpretative strategies for lung function tests
Pellegrino, R., Viegi, G., Brusasco, V., Crapo, R. O., Burgos, F., Casaburi, R., Coates, A., van der Grinten, C. P. M., Gustafsson, P., Hankinson, J., et al. (2005) · European Respiratory Journal · doi:10.1183/09031936.05.00035205 · Cited by 5,945
Graham, B. L., Steenbruggen, I., Miller, M. R., Barjaktarevic, I. Z., Cooper, B. G., Hall, G. L., Hallstrand, T. S., Kaminsky, D. A., McCarthy, K., McCormack, M. C., et al. (2019) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201908-1590st · Cited by 4,305
Spruit, M. A., Singh, S. J., Garvey, C., ZuWallack, R., Nici, L., Rochester, C., Hill, K., Holland, A. E., Lareau, S. C., Man, W. D.-C., et al. (2013) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201309-1634st · Cited by 3,938
ATS/ACCP statement on cardiopulmonary exercise testing
(2003) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.167.2.211 · Cited by 3,026
Metadata
- Authors
- Babb, T. G., Viggiano, R., Hurley, B., Staats, B., & Rodarte, J. R.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 1991-01-01
- Volume
- 70
- Issue
- 1
- Pages
- 223-230
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2163356000
- Cited by
- 195
- References
- 0
- FWCI
- 14.37
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Effect of mild-to-moderate airflow limitation on exercise capacity. https://app.cochat.ai/papers/10.1152/jappl.1991.70.1.223
- The paper
- Babb, T. G., Viggiano, R., Hurley, B., Staats, B., & Rodarte, J. R. (1991). Effect of mild-to-moderate airflow limitation on exercise capacity. Journal of Applied Physiology. https://doi.org/10.1152/jappl.1991.70.1.223
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.