The DOI matches its Crossref record.
pH-induced effects on median frequency and conduction velocity of the myoelectric signal
Abstract
H+ accumulation at the sarcolemma is believed to play a key role in determining the electrophysiological correlates of fatigue. This paper describes an in vitro method to externally manipulate muscle pH while measuring the resultant effect on surface-detected median frequency (MDF) and conduction velocity (CV) parameters. Hamster muscle diaphragm strips (n = 8) were isolated with the phrenic nerve intact and placed in an oxygenated Krebs bath (26 degrees C). The muscle was clamped to a noncompliant load cell to measure isometric contractile tension. Tetanic contraction was developed via 40-Hz supermaximal stimulation of the phrenic nerve. Differential signals were recorded from three electromyogram (EMG) detection surfaces for computation of CV (via the phase shift in the EMG signals) and MDF. Repeated trials were conducted at bath pHs of 7.4, 7.0, and 6.6. Bath pH was altered by aerating predetermined concentrations of O2 and CO2 into the bath. Decreases in bath pH resulted in decreases in both initial MDF and initial CV. The differences in initial MDF and initial CV were significant (P less than 0.001) for each of the bath pH conditions. In general, the change in bath pH resulted in an equal percent change in initial MDF and initial CV. This suggests that the change in bath pH caused a decrease in CV without significantly altering the fundamental shape of the M wave. In contrast, the EMG was altered differently during stimulated contractions. During stimulation, the rate of decay of CV was 65% of the rate of decay of MDF.(ABSTRACT TRUNCATED AT 250 WORDS)
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The Use of Surface Electromyography in Biomechanics
De Luca, C. J. (1997) · Journal of Applied Biomechanics · doi:10.1123/jab.13.2.135 · Cited by 3,268
Self-citationSurface EMG based muscle fatigue evaluation in biomechanics
Cifrek, M., Medved, V., Tonković, S., & Ostojić, S. (2009) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2009.01.010 · Cited by 954
St Clair Gibson, A., & Noakes, T. D. (2004) · British Journal of Sports Medicine · doi:10.1136/bjsm.2003.009852 · Cited by 485
von Tscharner, V. (2000) · Journal of Electromyography and Kinesiology · doi:10.1016/s1050-6411(00)00030-4 · Cited by 360
Motor unit recruitment for dynamic tasks: current understanding and future directions
Hodson-Tole, E. F., & Wakeling, J. M. (2009) · Journal of Comparative Physiology B · doi:10.1007/s00360-008-0289-1 · Cited by 145
Metadata
- Authors
- Brody, L. R., Pollock, M. T., Roy, S. H., De Luca, C. J., & Celli, B.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 1991-11-01
- Volume
- 71
- Issue
- 5
- Pages
- 1878-1885
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W1870746867
- Cited by
- 327
- References
- 0
- FWCI
- 4.25
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: pH-induced effects on median frequency and conduction velocity of the myoelectric signal. https://app.cochat.ai/papers/10.1152/jappl.1991.71.5.1878
- The paper
- Brody, L. R., Pollock, M. T., Roy, S. H., De Luca, C. J., & Celli, B. (1991). pH-induced effects on median frequency and conduction velocity of the myoelectric signal. Journal of Applied Physiology. https://doi.org/10.1152/jappl.1991.71.5.1878
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.