pH-induced effects on median frequency and conduction velocity of the myoelectric signal
The DOI matches its Crossref record.
Abstract
H+ accumulation at the sarcolemma is believed to play a key role in determining the electrophysiological correlates of fatigue. This paper describes an in vitro method to externally manipulate muscle pH while measuring the resultant effect on surface-detected median frequency (MDF) and conduction velocity (CV) parameters. Hamster muscle diaphragm strips (n = 8) were isolated with the phrenic nerve intact and placed in an oxygenated Krebs bath (26 degrees C). The muscle was clamped to a noncompliant load cell to measure isometric contractile tension. Tetanic contraction was developed via 40-Hz supermaximal stimulation of the phrenic nerve. Differential signals were recorded from three electromyogram (EMG) detection surfaces for computation of CV (via the phase shift in the EMG signals) and MDF. Repeated trials were conducted at bath pHs of 7.4, 7.0, and 6.6. Bath pH was altered by aerating predetermined concentrations of O2 and CO2 into the bath. Decreases in bath pH resulted in decreases in both initial MDF and initial CV. The differences in initial MDF and initial CV were significant (P less than 0.001) for each of the bath pH conditions. In general, the change in bath pH resulted in an equal percent change in initial MDF and initial CV. This suggests that the change in bath pH caused a decrease in CV without significantly altering the fundamental shape of the M wave. In contrast, the EMG was altered differently during stimulated contractions. During stimulation, the rate of decay of CV was 65% of the rate of decay of MDF.(ABSTRACT TRUNCATED AT 250 WORDS)
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The Use of Surface Electromyography in Biomechanics
De Luca, C. J. (1997) · Journal of Applied Biomechanics · doi:10.1123/jab.13.2.135 · Cited by 3,268
Self-citationSurface EMG based muscle fatigue evaluation in biomechanics
Cifrek, M., Medved, V., Tonković, S., & Ostojić, S. (2009) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2009.01.010 · Cited by 954
St Clair Gibson, A., & Noakes, T. D. (2004) · British Journal of Sports Medicine · doi:10.1136/bjsm.2003.009852 · Cited by 485
von Tscharner, V. (2000) · Journal of Electromyography and Kinesiology · doi:10.1016/s1050-6411(00)00030-4 · Cited by 360
Burd, N. A., Holwerda, A. M., Selby, K. C., West, D. W. D., Staples, A. W., Cain, N. E., Cashaback, J. G. A., Potvin, J. R., Baker, S. K., & Phillips, S. M. (2010) · The Journal of Physiology · doi:10.1113/jphysiol.2010.192856 · Cited by 317
Bilodeau, M., Schindler-Ivens, S., Williams, D. M., Chandran, R., & Sharma, S. S. (2003) · Journal of Electromyography and Kinesiology · doi:10.1016/s1050-6411(02)00050-0 · Cited by 249
Clark, B. C., Manini, T. M., Thé, D. J., Doldo, N. A., & Ploutz-Snyder, L. L. (2003) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00926.2002 · Cited by 223
“There is strong evidence that spectral compression of the interference EMG signal during a sustained submaximal contraction is due to a slowing of conduction velocity caused by metabolic shifts (decreased muscle pH) in the active skeletal muscle (4, 7, 11, 23, 25, 30, 31, 39, 47).”
Kankaanpää, M., Laaksonen, D., Taimela, S., Kokko, S.-M., Airaksinen, O., & Hänninen, O. (1998) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/s0003-9993(98)90173-3 · Cited by 196
Potvin, J. R., & Bent, L. R. (1997) · Journal of Electromyography and Kinesiology · doi:10.1016/s1050-6411(96)00025-9 · Cited by 182
Mannion, A. F. (1999) · Journal of Electromyography and Kinesiology · doi:10.1016/s1050-6411(99)00010-3 · Cited by 170
“[17] Brody LR, Pollock MT, Roy SH, DeLuca CJ, Celli B.”
BackgroundFalla, D., Gizzi, L., Tschapek, M., Erlenwein, J., & Petzke, F. (2014) · Pain · doi:10.1016/j.pain.2014.01.027 · Cited by 167
“A greater reduction in mean frequency over time can occur as a result of a greater accumulation of metabolic by-products, including potassium and lactic acid [10].”
BackgroundActivation imbalances in lumbar spine muscles in the presence of chronic low back pain
Oddsson, L. I. E., & De Luca, C. J. (2003) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01183.2001 · Cited by 147
Motor unit recruitment for dynamic tasks: current understanding and future directions
Hodson-Tole, E. F., & Wakeling, J. M. (2009) · Journal of Comparative Physiology B · doi:10.1007/s00360-008-0289-1 · Cited by 145
Muscle activation during three sets to failure at 80 vs. 30 % 1RM resistance exercise
Jenkins, N. D. M., Housh, T. J., Bergstrom, H. C., Cochrane, K. C., Hill, E. C., Smith, C. M., Johnson, G. O., Schmidt, R. J., & Cramer, J. T. (2015) · European Journal of Applied Physiology · doi:10.1007/s00421-015-3214-9 · Cited by 140
Grgic, J., Pedisic, Z., Saunders, B., Artioli, G. G., Schoenfeld, B. J., McKenna, M. J., Bishop, D. J., Kreider, R. B., Stout, J. R., Kalman, D. S., et al. (2021) · Journal of the International Society of Sports Nutrition · doi:10.1186/s12970-021-00458-w · Cited by 138
Onishi, H., Yagi, R., Akasaka, K., Momose, K., Ihashi, K., & Handa, Y. (2000) · Journal of Electromyography and Kinesiology · doi:10.1016/s1050-6411(99)00020-6 · Cited by 105
Muscle fatigue induced by two different resistances: Elastic tubing versus weight machines
Melchiorri, G., & Rainoldi, A. (2011) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2011.07.015 · Cited by 82
“, 1995), is known to be reflected in the surface EMG variable time courses: an increase of signal amplitude and a decrease of power spectra frequencies and muscle fiber conduction velocity (Merletti et al., 1990; Brody et al., 1991; Merletti et al., 2004) during sustained contractions.”
Background
Metadata
- Authors
- Brody, L. R., Pollock, M. T., Roy, S. H., De Luca, C. J., & Celli, B.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 1991-11-01
- Volume
- 71
- Issue
- 5
- Pages
- 1878-1885
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W1870746867
- Cited by
- 327
- References
- 0
- FWCI
- 4.25
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.