Analysis of human chest wall motion using a two-compartment rib cage model
The DOI matches its Crossref record.
Abstract
We present a model of chest wall mechanics that extends the model described previously by Macklem et al. (J. Appl. Physiol. 55: 547–557, 1983) and incorporates a two-compartment rib cage. We divide the rib cage into that apposed to the lung (RCpul) and that apposed to the diaphragm (RCab). We apply this model to determine rib cage distortability, the mechanical coupling between RCpul and RCab, the contribution of the rib cage muscles to the pressure change during spontaneous inspiration (Prcm), and the insertional component of transdiaphragmatic pressure in humans. We define distortability as the relationship between distortion and transdiaphragmatic pressure (Pdi) and mechanical coupling as the relationship between rib cage distortion and the pressure acting to restore the rib cage to its relaxed configuration (Plink), as assessed during bilateral transcutaneous phrenic nerve stimulation. Prcm was calculated at end inspiration as the component of the pressure displacing RCpul not accounted for by Plink or pleural pressure. Prcm and Plink were approximately equal during quiet breathing, contributing 3.7 and 3.3 cmH2O on average during breaths associated with a change in Pdi of 3.9 cmH2O. The insertional component of Pdi was measured as the pressure acting on RCab not accounted for by the change in abdominal pressure during an inspiration without rib cage distortion and was 40 +/- 12% (SD) of total Pdi. We conclude that there is substantial resistance of the human rib cage to distortion, that, along with rib cage muscles, contributes importantly to the fall in pleural pressure over the costal surface of the lung.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Chest wall and lung volume estimation by optical reflectance motion analysis
Cala, S. J., Kenyon, C. M., Ferrigno, G., Carnevali, P., Aliverti, A., Pedotti, A., Macklem, P. T., & Rochester, D. F. (1996) · Journal of Applied Physiology · doi:10.1152/jappl.1996.81.6.2680 · Cited by 377
Self-citationChest wall motion during tidal breathing
De Groote, A., Wantier, M., Cheron, G., Estenne, M., & Paiva, M. (1997) · Journal of Applied Physiology · doi:10.1152/jappl.1997.83.5.1531 · Cited by 258
Mechanics of respiratory muscles
Ratnovsky, A., Elad, D., & Halpern, P. (2008) · Respiratory Physiology & Neurobiology · doi:10.1016/j.resp.2008.04.019 · Cited by 197
Aliverti, A., Dellacà, R., Pelosi, P., Chiumello, D., Gattinoni, L., & Pedotti, A. (2001) · Annals of Biomedical Engineering · doi:10.1114/1.1332084 · Cited by 186
Chest wall volume and asynchrony in stroke and Parkinson’s disease subjects: A case-control study
Florêncio, R. B., da Nobrega, A. J. S., Lima, Í. N. D. F., Gualdi, L. P., Cabral, E. E., Fagundes, M. L. L. C., Aliverti, A., Resqueti, V. R., & Fregonezi, G. A. D. F. (2019) · PLOS ONE · doi:10.1371/journal.pone.0216641 · Cited by 19
Compartmental chest wall volume changes during volitional normocapnic hyperpnoea
Illi, S. K., Hostettler, S., Mohler, E., Aliverti, A., & Spengler, C. M. (2011) · Respiratory Physiology & Neurobiology · doi:10.1016/j.resp.2011.05.007 · Cited by 9
Metadata
- Authors
- Ward, M. E., Ward, J. W., & Macklem, P. T.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 1992-04-01
- Volume
- 72
- Issue
- 4
- Pages
- 1338-1347
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W1912865552
- Cited by
- 126
- References
- 0
- FWCI
- 0.43
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.