The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Chest wall and lung volume estimation by optical reflectance motion analysis
Abstract
Cala, S. J., C. M. Kenyon, G. Ferrigno, P. Carnevali, A. Aliverti, A. Pedotti, P. T. Macklem, and D. F. Rochester. Chest wall and lung volume estimation by optical reflectance motion analysis. J. Appl. Physiol. 81(6): 2680–2689, 1996.—Estimation of chest wall motion by surface measurements only allows one-dimensional measurements of the chest wall. We have assessed an optical reflectance system (OR), which tracks reflective markers in three dimensions (3-D) for respiratory use. We used 86 (6-mm-diameter) hemispherical reflective markers arranged circumferentially on the chest wall in seven rows between the sternal notch and the anterior superior iliac crest in two normal standing subjects. We calculated the volume of the entire chest wall and compared inspired and expired volumes with volumes obtained by spirometry. Marker positions were recorded by four TV cameras; two were 4 m in front of and two were 4 m behind the subject. The TV signals were sampled at 100 Hz and combined with grid calibration parameters on a personal computer to obtain the 3-D coordinates of the markers. Chest wall surfaces were reconstructed by triangulation through the point data, and chest wall volume was calculated. During tidal breathing and vital capacity maneuvers and during CO 2-stimulated hyperpnea, there was a very close correlation of the lung volumes (Vl) estimated by spirometry [Vl(SP)] and OR [Vl(OR)]. Regression equations of Vl(OR) ( y) vs. Vl(SP) ( x,btps in liters) for the two subjects were given by y = 1.01 x − 0.01 ( r = 0.996) and y = 0.96 x + 0.03 ( r = 0.997), and by y = 1.04 x + 0.25 ( r = 0.97) and y = 0.98 x + 0.14 ( r = 0.95) for the two maneuvers, respectively. We conclude spirometric volumes can be estimated very accurately and directly from chest wall surface markers, and we speculate that OR may be usefully applied to calculations of chest wall shape, regional volumes, and motion analysis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Plum, F. (1960) · Archives of Neurology · doi:10.1001/archneur.1960.03840090124020 · Cited by 10,364
Sorokin, S. P. (1983) · Histology · doi:10.1007/978-1-349-06859-3_23 · Cited by 1,782
Measurement of the separate volume changes of rib cage and abdomen during breathing
Konno, K., & Mead, J. (1967) · Journal of Applied Physiology · doi:10.1152/jappl.1967.22.3.407 · Cited by 1,027
Elite: A Digital Dedicated Hardware System for Movement Analysis Via Real-Time TV Signal Processing
Ferrigno, G., & Pedotti, A. (1985) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1985.325627 · Cited by 576
Self-citationCalibration of respiratory inductive plethysmograph during natural breathing
Sackner, M. A., Watson, H., Belsito, A. S., Feinerman, D., Suarez, M., Gonzalez, G., Bizousky, F., & Krieger, B. (1989) · Journal of Applied Physiology · doi:10.1152/jappl.1989.66.1.410 · Cited by 375
(2002) · Springer eBooks · doi:10.1007/978-88-470-2916-3 · Cited by 320
Mouchnino, L., Aurenty, R., Massion, J., & Pedotti, A. (1992) · Journal of Neurophysiology · doi:10.1152/jn.1992.67.6.1587 · Cited by 229
Self-citationAnalysis of human chest wall motion using a two-compartment rib cage model
Ward, M. E., Ward, J. W., & Macklem, P. T. (1992) · Journal of Applied Physiology · doi:10.1152/jappl.1992.72.4.1338 · Cited by 126
Self-citationPattern recognition in 3D automatic human motion analysis
Ferrigno, G., Borghese, N. A., & Pedotti, A. (1990) · ISPRS Journal of Photogrammetry and Remote Sensing · doi:10.1016/0924-2716(90)90046-e · Cited by 83
Self-citationRegional differences in abdominal pressure swings in dogs
Decramer, M., Troyer, A. D., Kelly, S., Zocchi, L., & Macklem, P. T. (1984) · Journal of Applied Physiology · doi:10.1152/jappl.1984.57.6.1682 · Cited by 72
Self-citation
Cited by
ERS statement on respiratory muscle testing at rest and during exercise
Laveneziana, P., Albuquerque, A., Aliverti, A., Babb, T., Barreiro, E., Dres, M., Dubé, B.-P., Fauroux, B., Gea, J., Guenette, J. A., et al. (2019) · European Respiratory Journal · doi:10.1183/13993003.01214-2018 · Cited by 818
Self-citationHeart rate measurement based on a time-lapse image.
Takano, C., & Ohta, Y. (2007) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2006.09.006 · Cited by 345
Regional chest wall volumes during exercise in chronic obstructive pulmonary disease
Aliverti, A. (2004) · Thorax · doi:10.1136/thorax.2003.011494 · Cited by 226
Self-citationChest Wall Kinematics and Breathlessness During Pursed-Lip Breathing in Patients With COPD
Bianchi, R., Gigliotti, F., Romagnoli, I., Lanini, B., Castellani, C., Grazzini, M., & Scano, G. (2004) · Chest · doi:10.1378/chest.125.2.459 · Cited by 144
Ciocchetti, M., Massaroni, C., Saccomandi, P., Caponero, M., Polimadei, A., Formica, D., & Schena, E. (2015) · Biosensors · doi:10.3390/bios5030602 · Cited by 142
Metadata
- Authors
- Cala, S. J., Kenyon, C. M., Ferrigno, G., Carnevali, P., Aliverti, A., Pedotti, A., Macklem, P. T., & Rochester, D. F.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 1996-12-01
- Volume
- 81
- Issue
- 6
- Pages
- 2680-2689
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W1945187647
- Cited by
- 377
- References
- 15
- FWCI
- 2.44
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Chest wall and lung volume estimation by optical reflectance motion analysis. https://app.cochat.ai/papers/10.1152/jappl.1996.81.6.2680
- The paper
- Cala, S. J., Kenyon, C. M., Ferrigno, G., Carnevali, P., Aliverti, A., Pedotti, A., Macklem, P. T., & Rochester, D. F. (1996). Chest wall and lung volume estimation by optical reflectance motion analysis. Journal of Applied Physiology. https://doi.org/10.1152/jappl.1996.81.6.2680
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.