Seven-day validation of doubly labeled water method using indirect room calorimetry
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Carbon dioxide production, water production, and energy expenditure (EE) determined with 2H2(18)O were validated using a room calorimeter. Nine human subjects (5 males, 4 females) resided in the calorimeter for five to seven consecutive 23.5-h days. Daily carbon dioxide and water production and EE were averaged from calorimeter data and compared with 2H2(18)O results for the same period and for the following week. Isotope concentrations were measured by isotope ratio mass spectroscopy (18O) and infrared spectrophotometry (2H). Isotope clearance rates and pool sizes were determined by two multipoint methods and the two-point method. No significant differences were measured between calorimetry and 2H2(18)O results for the period within the chamber [multipoint A.M. urine 1.55% +/- 2.57 (SD) %, multipoint A.M. + P.M. urine 0.98% +/- 8.19%, two-point 1.59% +/- 4.50%]. Free-living EE was 13% +/- 7% greater. The results indicate that the 2H2(18)O method as applied is a valid technique for measuring EE, that multipoint calculation methods can be as precise as the two-point method, and that EE was greater in free-living than in calorimeter-confined conditions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Estimation of total body water by bioelectrical impedance analysis in blacks
Zillikens, M. C., & Conway, J. M. (1991) · American Journal of Human Biology · doi:10.1002/ajhb.1310030106 · Cited by 45 · cited 1×
“The subjects' bioelectrical impedances (BIA) (BIA-101; RJL Systems, Detroit, MI) were measured to determine body lean body mass and percent body fat (26).”
MethodSelf-citation
Cited by
Moshfegh, A. J., Rhodes, D. G., Baer, D. J., Murayi, T., Clemens, J. C., Rumpler, W. V., Paul, D. R., Sebastian, R. S., Kuczynski, K. J., Ingwersen, L. A., et al. (2008) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/88.2.324 · Cited by 1,982
Steinbeck, K. S. (2001) · Obesity Reviews · doi:10.1046/j.1467-789x.2001.00033.x · Cited by 312
The history and theory of the doubly labeled water technique
John, R. S. (1998) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/68.4.932s · Cited by 293
Brage, S., Westgate, K., Franks, P. W., Stegle, O., Wright, A., Ekelund, U., & Wareham, N. J. (2015) · PLOS ONE · doi:10.1371/journal.pone.0137206 · Cited by 151
“Free-living energy expenditure was assessed with the doubly-labelled water (DLW) technique, which is the best standard for assessing TEE during free-living conditions and also compares favourably against whole-body calorimetry [2,3].”
MethodA standard calculation methodology for human doubly labeled water studies
Speakman, J. R., Yamada, Y., Sagayama, H., Berman, E. S. F., Ainslie, P. N., Andersen, L. F., Anderson, L. J., Arab, L., Baddou, I., Bedu-Addo, K., et al. (2021) · Cell Reports Medicine · doi:10.1016/j.xcrm.2021.100203 · Cited by 143
Metadata
- Authors
- Seale, J. L., Conway, J. M., & Canary, J. J.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 1993-01-01
- Volume
- 74
- Issue
- 1
- Pages
- 402-409
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2254111391
- Cited by
- 64
- References
- 1
- FWCI
- 1.04
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Seven-day validation of doubly labeled water method using indirect room calorimetry. https://app.cochat.ai/papers/10.1152/jappl.1993.74.1.402
- The paper
- Seale, J. L., Conway, J. M., & Canary, J. J. (1993). Seven-day validation of doubly labeled water method using indirect room calorimetry. Journal of Applied Physiology. https://doi.org/10.1152/jappl.1993.74.1.402
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.