Thermoregulatory responses to hyperthermia during isoflurane anesthesia in humans
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The authors tested the hypotheses that isoflurane anesthesia increases the threshold for sweating but minimally decreases the gain (sensitivity) or maximum intensity of this response and that thermoregulatory responses to hyperthermia are similar in anesthetized men and women. Sweating in response to core hyperthermia was studied in five men and five women during 0, 0.8, and 1.2% end-tidal isoflurane anesthesia. Thigh sweating was quantified by measuring gas flow, relative humidity, and temperature passing over a known surface area. The distal esophageal temperature triggering sweating was considered the sweating threshold, and gain was defined as the core temperature increment required to increase sweating rate from 25 to 75% of maximum observed intensity. The sweating threshold increased linearly with isoflurane concentration from 36.6 +/- 0.1 to 38.1 +/- 0.1 degrees C in the men and from 37.1 +/- 0.3 to 38.3 +/- 0.2 degrees C in the women. The thresholds were significantly higher in women than in men. Gain and maximum sweating intensities were similar at each anesthetic concentration and in men and women. These data indicate that isoflurane anesthesia significantly increases the threshold triggering thermoregulatory sweating but that gain and maximum sweating rate are relatively well preserved.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Importance of skin temperature in the regulation of sweating.
Nadel, E. R., Bullard, R. W., & Stolwijk, J. A. (1971) · Journal of Applied Physiology · doi:10.1152/jappl.1971.31.1.80 · Cited by 545
Cited by
Temperature Monitoring and Perioperative Thermoregulation
Sessler, D. I., Warner, D. S., & Warner, M. A. (2008) · Anesthesiology · doi:10.1097/aln.0b013e31817f6d76 · Cited by 758
“From Washington et al.(75); used with permission.”
BackgroundMethodInfluentialSelf-citationHeat Flow and Distribution during Induction of General Anesthesia
Matsukawa, T., Sessler, D. I., Sessler, A. M., Schroeder, M., Ozaki, M., Kurz, A., & Cheng, C. (1995) · Anesthesiology · doi:10.1097/00000542-199503000-00008 · Cited by 528
Self-citationThermoregulation, mild perioperative hypothermia and post-anaesthetic shivering
Buggy, D. J., & Crossley, A. W. A. (2000) · British Journal of Anaesthesia · doi:10.1093/bja/84.5.615 · Cited by 335
Propofol Linearly Reduces the Vasoconstriction and Shivering Thresholds
Matsukawa, T., Kurz, A., Sessler, D. I., Bjorksten, A. R., Merrifield, B., & Cheng, C. (1995) · Anesthesiology · doi:10.1097/00000542-199505000-00012 · Cited by 330
Self-citationPhysiology of Thermoregulation
Kurz, A. (2008) · Best Practice & Research Clinical Anaesthesiology · doi:10.1016/j.bpa.2008.06.004 · Cited by 222
Metadata
- Authors
- Washington, D. E., Sessler, D. I., Moayeri, A., Merrifield, B., McGuire, J., Prager, M., Belani, K., Hudson, S., & Schroeder, M.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 1993-01-01
- Volume
- 74
- Issue
- 1
- Pages
- 82-87
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2113283874
- Cited by
- 94
- References
- 1
- FWCI
- 6.66
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.