Determination of maximal power output at neuromuscular fatigue threshold
The DOI matches its Crossref record.
Abstract
The purpose of this study was to determine the maximal power output at the neuromuscular fatigue threshold (EMGFT), as estimated from electromyographic (EMG) data from representative leg muscles during cycling. The rate of rise in integrated EMG activity as a function of time (iEMG slope) was calculated at each of four constant-power-output ergometer bouts for 20 subjects. The iEMG slopes were plotted against work rates that were well described as linear functions (0.84 < R2 < 0.99). This iEMG slope vs. work rate relationship was extrapolated to zero slope to give an intercept on the power axis that was interpreted as the highest work rate sustainable without EMG evidence of neuromuscular fatigue (EMGFT). Each individual EMGFT was then expressed in terms of an O2 output (VO2) equivalent on the basis of the individual delta efficiency calculated during a linearly increasing maximal exercise test on the same bicycle ergometer. Results indicated a highly significant correlation (r = 0.92, P < 0.01) between EMGFT VO2 and anaerobic threshold VO2, as determined by conventional gas exchange criteria. The mean EMGFT VO2 (1.84 +/- 0.55 l/min) was, however, significantly greater (P < 0.01) than the anaerobic threshold VO2 (1.72 +/- 0.54 l/min). It was suggested that the EMGFT may provide an attractive alternative to the measurement of the highest work rate that can be sustained without evidence of neuromuscular fatigue.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The Effect of Endurance Training on Parameters of Aerobic Fitness
Jones, A. M., & Carter, H. (2000) · Sports Medicine · doi:10.2165/00007256-200029060-00001 · Cited by 935
“[118,119] It is possible that a greater oxidative enzyme complement in type I muscle fibres might delay the point at which the type II muscle fibres are recruited during exercise.[135] Furthermore, an increase in the oxidative potential of the type II fibres might reduce their reliance on anaerobic glycolysis for ATP…”
BackgroundSt Clair Gibson, A., & Noakes, T. D. (2004) · British Journal of Sports Medicine · doi:10.1136/bjsm.2003.009852 · Cited by 485
Muscle fiber type diversification during exercise and regeneration
Qaisar, R., Bhaskaran, S., & Van Remmen, H. (2016) · Free Radical Biology and Medicine · doi:10.1016/j.freeradbiomed.2016.03.025 · Cited by 283
Effect of beta-alanine supplementation on muscle carnosine concentrations and exercise performance
Sale, C., Saunders, B., & Harris, R. C. (2010) · Amino Acids · doi:10.1007/s00726-009-0443-4 · Cited by 238
“There was some early experimental support for this assertion as Severin et al. (1953) demonstrated that, when in the presence of carnosine, electrically stimulated frog sartorius muscle was more resistant to fatigue.”
BackgroundResultHusmann, F., Bruhn, S., Mittlmeier, T., Zschorlich, V., & Behrens, M. (2019) · Frontiers in Physiology · doi:10.3389/fphys.2019.00404 · Cited by 77
Metadata
- Authors
- Moritani, T., Takaishi, T., & Matsumoto, T.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 1993-04-01
- Volume
- 74
- Issue
- 4
- Pages
- 1729-1734
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W1940483143
- Cited by
- 144
- References
- 0
- FWCI
- 4.88
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Determination of maximal power output at neuromuscular fatigue threshold. https://app.cochat.ai/papers/10.1152/jappl.1993.74.4.1729
- The paper
- Moritani, T., Takaishi, T., & Matsumoto, T. (1993). Determination of maximal power output at neuromuscular fatigue threshold. Journal of Applied Physiology. https://doi.org/10.1152/jappl.1993.74.4.1729
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.