Theory and measurements of snores
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Upper airway narrowing, collapsibility, and resistance are recognized predisposing factors for snoring and obstructive sleep apnea, but the mechanisms of their action and interaction are not known. We studied a simple theoretical model of the upper airways, consisting of a movable wall in a channel segment that connects to the airway opening via a conduit with a resistance. Inspiratory flow (V) through the channel segment causes local pressure changes due to viscous losses and the Bernoulli force that may overcome the elastic forces acting on the movable wall. The model predicts instability leading to upper airway closure over a wide range of parameter values. Increasing inspiratory V above a boundary, determined by values of upper airway resistance, segment compliance, length, width, and diameter, as well as gas density, leads to a dynamic airway closure. The mathematical model establishes the power relationships between parameters and provides physiologically realistic quantitative simulation of upper airway closure when values are adapted from literature and from radiographic measurements of upper airway motion induced by negative pressure. The rate of appearance of repetitive sound structures during snoring was favorably compared with the model's prediction of the time course of wall motion during collapse. V measurements during simulated snores revealed an asymmetric oscillatory pattern compatible with repetitive upper airway closure. We conclude that snoring may be modeled as a series of dynamic closure events of the upper airways. The model predicts that the width and length of the movable portion of the upper airways and the gas density are likely to affect the onset of snoring, in addition to other, previously recognized, parameters.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Sullivan, C., Berthon-Jones, M., Issa, F., & Eves, L. (1981) · The Lancet · doi:10.1016/s0140-6736(81)92140-1 · Cited by 2,731
Cited by
The upper airway in sleep: physiology of the pharynx
Ayappa, I., & Rapoport, D. M. (2003) · Sleep Medicine Reviews · doi:10.1053/smrv.2002.0238 · Cited by 340
Computer based sleep recording and analysis
Penzel, T., & Conradt, R. (2000) · Sleep Medicine Reviews · doi:10.1053/smrv.1999.0087 · Cited by 235
Chang, E.-T., Yang, M.-C., Wang, H.-M., & Lai, H.-L. (2014) · Sleep and Breathing · doi:10.1007/s11325-013-0860-1 · Cited by 18
The Efficacy of Low-Level Continuous Positive Airway Pressure for the Treatment of Snoring
Guzman, M. A., Sgambati, F. P., Pho, H., Arias, R. S., Hawks, E. M., Wolfe, E. M., Ötvös, T., Rosenberg, R., Dakheel, R., Schneider, H., et al. (2017) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.6588 · Cited by 12
Metadata
- Authors
- Gavriely, N., & Jensen, O.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 1993-06-01
- Volume
- 74
- Issue
- 6
- Pages
- 2828-2837
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W1808857894
- Cited by
- 85
- References
- 1
- FWCI
- 1.46
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Theory and measurements of snores. https://app.cochat.ai/papers/10.1152/jappl.1993.74.6.2828
- The paper
- Gavriely, N., & Jensen, O. (1993). Theory and measurements of snores. Journal of Applied Physiology. https://doi.org/10.1152/jappl.1993.74.6.2828
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.