The DOI matches its Crossref record.
Neurocirculatory consequences of negative intrathoracic pressure vs. asphyxia during voluntary apnea
Abstract
To investigate the mechanisms responsible for fluctuations in arterial pressure and sympathetic nerve activity that occur during obstructive sleep apnea, we studied neurocirculatory responses to Mueller maneuvers and breath holds in conscious humans. During 20-s Mueller maneuvers at -40 mmHg, mean arterial pressure fell initially (-11 +/- 3 mmHg) and then rose above baseline (+8 +/- 3 mmHg) on release of the inspiratory strain. Sympathetic outflow to skeletal muscle was almost completely suppressed during the initial moments of the maneuver and rose to more than three times the baseline level at the termination of the maneuver. Simple 20-s breath holds were accompanied by time-dependent increases in both arterial pressure (+11 +/- 3 mmHg) and sympathetic nerve activity (> 3 times baseline). The administration of supplemental O2 greatly attenuated the increases in arterial pressure and sympathetic nerve activity during Mueller maneuvers and breath holds. We conclude that carotid chemoreflex stimulation is the primary mechanism responsible for apnea-induced sympathetic activation during wakefulness and that it may contribute importantly to the sympathetic activation that accompanies sleep-disordered breathing.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Pathophysiology of Sleep Apnea
Dempsey, J. A., Veasey, S. C., Morgan, B. J., & O'Donnell, C. P. (2010) · Physiological Reviews · doi:10.1152/physrev.00043.2008 · Cited by 2,243
“In contrast, the mechanical influence of negative intrathoracic pressure plays little or no role in causing the sympathetically mediated pressor response to apnea (424, 720).”
BackgroundSelf-citationObstructive Sleep Apnea: Implications for Cardiac and Vascular Disease
Shamsuzzaman, A. S. M., Gersh, B. J., & Somers, V. K. (2003) · JAMA · doi:10.1001/jama.290.14.1906 · Cited by 1,188
Sleep Apnea and Cardiovascular Disease
LEUNG, R. S. T., & DOUGLAS BRADLEY, T. (2001) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.164.12.2107045 · Cited by 649
Sleep Apnea and Heart Failure: Part I: Obstructive Sleep Apnea
Bradley, T. D., & Floras, J. S. (2003) · Circulation · doi:10.1161/01.cir.0000061757.12581.15 · Cited by 554
Hemodynamic Effects of Simulated Obstructive Apneas in Humans With and Without Heart Failure
Bradley, T. D., Hall, M. J., Ando, S.-I., & Floras, J. S. (2001) · Chest · doi:10.1378/chest.119.6.1827 · Cited by 216
Metadata
- Authors
- Morgan, B. J., Denahan, T., & Ebert, T. J.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 1993-06-01
- Volume
- 74
- Issue
- 6
- Pages
- 2969-2975
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W1852307386
- Cited by
- 184
- References
- 0
- FWCI
- 2.08
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Neurocirculatory consequences of negative intrathoracic pressure vs. asphyxia during voluntary apnea. https://app.cochat.ai/papers/10.1152/jappl.1993.74.6.2969
- The paper
- Morgan, B. J., Denahan, T., & Ebert, T. J. (1993). Neurocirculatory consequences of negative intrathoracic pressure vs. asphyxia during voluntary apnea. Journal of Applied Physiology. https://doi.org/10.1152/jappl.1993.74.6.2969
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.