The DOI matches its Crossref record.
Tracheal and neck position influence upper airway airflow dynamics by altering airway length
Abstract
Upper airway obstruction during sleep is characterized by inspiratory airflow limitation and reductions in maximal inspiratory airflow (VImax). To determine how mechanical factors modulate VImax, we analyzed pressure-flow relationships obtained in the isolated upper airway of paralyzed cats. VImax and its determinants, the pharyngeal critical pressure (Pcrit) and the nasal resistance (Rn) upstream to the flow-limiting site (FLS), were measured as caudal tracheal displacement, neck position, and airway length were systematically varied. As the proximal tracheal stump was displaced caudally, graded increases in VImax from 145.3 +/- 90.8 (SD) to 285.9 +/- 117.5 ml/s (P < 0.02) and decreases in Pcrit from -3.0 +/- 3.0 to -9.5 +/- 3.4 cmH2O (P < 0.002) were seen without any significant change in Rn. During neck flexion, significant decreases in VImax from 192.1 +/- 68.5 to 87.2 +/- 48.4 ml/s (P = 0.001), increases in Pcrit from -5.3 +/- 2.03 cmH2O to -1.6 +/- 1.4 cmH2O (P < 0.001), and decreases in Rn from 29.7 +/- 12.2 cmH2O.l-1.s to 16.2 +/- 8.9 cmH2O.l-1.s (P < 0.001) were noted compared with the neutral or extended neck position. Relative to the neutral airway length, upper airway length was found to decrease by 1.15 +/- 0.14 cm during neck flexion and to lengthen by 0.45 +/- 0.12 cm during neck extension. When tracheal displacement and neck position were altered, VImax and Rn correlated directly and Pcrit correlated inversely with airway length (P < 0.001). We conclude that alterations in airflow mechanics with caudal tracheal displacement and changes in neck positions are primarily due to alterations in airway length.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Obesity and Obstructive Sleep Apnea: Pathogenic Mechanisms and Therapeutic Approaches
Schwartz, A. R., Patil, S. P., Laffan, A. M., Polotsky, V., Schneider, H., & Smith, P. L. (2008) · Proceedings of the American Thoracic Society · doi:10.1513/pats.200708-137mg · Cited by 730
Self-citationAnatomy of pharynx in patients with obstructive sleep apnea and in normal subjects
Isono, S., Remmers, J. E., Tanaka, A., Sho, Y., Sato, J., & Nishino, T. (1997) · Journal of Applied Physiology · doi:10.1152/jappl.1997.82.4.1319 · Cited by 534
Pathophysiology of Upper Airway Obstruction: a Developmental Perspective
Arens, R., & Marcus, C. L. (2004) · Sleep · doi:10.1093/sleep/27.5.997 · Cited by 432
Collapsibility of the Upper Airway at Different Concentrations of Propofol Anesthesia
Eastwood, P. R., Platt, P. R., Shepherd, K., Maddison, K., & Hillman, D. R. (2005) · Anesthesiology · doi:10.1097/00000542-200509000-00007 · Cited by 364
WATANABE, T., ISONO, S., TANAKA, A., TANZAWA, H., & NISHINO, T. (2002) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.165.2.2009032 · Cited by 317
Metadata
- Authors
- Thut, D. C., Schwartz, A. R., Roach, D., Wise, R. A., Permutt, S., & Smith, P. L.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 1993-11-01
- Volume
- 75
- Issue
- 5
- Pages
- 2084-2090
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2151961444
- Cited by
- 178
- References
- 0
- FWCI
- 0.83
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Tracheal and neck position influence upper airway airflow dynamics by altering airway length. https://app.cochat.ai/papers/10.1152/jappl.1993.75.5.2084
- The paper
- Thut, D. C., Schwartz, A. R., Roach, D., Wise, R. A., Permutt, S., & Smith, P. L. (1993). Tracheal and neck position influence upper airway airflow dynamics by altering airway length. Journal of Applied Physiology. https://doi.org/10.1152/jappl.1993.75.5.2084
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.