Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 534

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Anatomy of pharynx in patients with obstructive sleep apnea and in normal subjects

Isono, Shiroh, Remmers, John E., Tanaka, Atsuko, Sho, Yasuhide, Sato, Jiro, Nishino, Takashi·1997·Journal of Applied Physiology

Abstract

Isono, Shiroh, John E Remmers, Atsuko Tanaka, Yasuhide Sho, Jiro Sato, and Takashi Nishino. Anatomy of pharynx in patients with obstructive sleep apnea and in normal subjects. J. Appl. Physiol. 82(4): 1319–1326, 1997.—Anatomic abnormalities of the pharynx are thought to play a role in the pathogenesis of obstructive sleep apnea (OSA), but their contribution has never been conclusively proven. The present study tested this anatomic hypothesis by comparing the mechanics of the paralyzed pharynx in OSA patients and in normal subjects. According to evaluation of sleep-disordered breathing (SDB) by nocturnal oximetry, subjects were divided into three groups: normal group ( n = 17), SDB-1 ( n = 18), and SDB-2 ( n = 22). The static pressure-area relationship of the passive pharynx was quantified under general anesthesia with complete paralysis. Age and body mass index were matched among the three groups. The site of the primary closure was the velopharynx in 49 subjects and the oropharynx in only 8 subjects. Distribution of the location of the primary closure did not differ among the groups. Closing pressure (Pc) of the velopharynx for SDB-1 and SDB-2 groups (0.90 ± 1.34 and 2.78 ± 2.78 cmH 2 O, respectively) was significantly higher than that for the normal group (−3.77 ± 3.44 cmH 2 O; P < 0.01). Maximal velopharyngeal area for the normal group (2.10 ± 0.85 cm 2) was significantly greater than for SDB-1 and SDB-2 groups (1.15 ± 0.46 and 1.06 ± 0.75 cm 2, respectively). The shape of the pressure-area curve for the velopharynx differed between normal subjects and patients with SDB, being steeper in slope near Pc in patients with SDB. Multivariate analysis of mechanical parameters and oxygen desaturation index (ODI) revealed that velopharyngeal Pc was the only variable highly correlated with ODI. Velopharyngeal Pc was associated with oropharyngeal Pc, suggesting mechanical interdependence of these segments. We conclude that the passive pharynx is more narrow and collapsible in sleep-apneic patients than in matched controls and that velopharyngeal Pc is the principal correlate of the frequency of nocturnal desaturations.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1152/jappl.1997.82.4.1319

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

See all 534

Metadata

Authors
Isono, S., Remmers, J. E., Tanaka, A., Sho, Y., Sato, J., & Nishino, T.
Venue
Journal of Applied Physiology
Published
1997-04-01
Volume
82
Issue
4
Pages
1319-1326
ISSN
  • 0161-7567 (ISSN-L)
  • 8750-7587
  • 1522-1601
OpenAlex
W2162645075
Cited by
534
References
6
FWCI
6.70
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Anatomy of pharynx in patients with obstructive sleep apnea and in normal subjects. https://app.cochat.ai/papers/10.1152/jappl.1997.82.4.1319
The paper
Isono, S., Remmers, J. E., Tanaka, A., Sho, Y., Sato, J., & Nishino, T. (1997). Anatomy of pharynx in patients with obstructive sleep apnea and in normal subjects. Journal of Applied Physiology. https://doi.org/10.1152/jappl.1997.82.4.1319

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.