Canine model of obstructive sleep apnea: model description and preliminary application
The DOI matches its Crossref record.
Abstract
This report describes a canine model of obstructive sleep apnea (OSA) developed in our laboratory and the results of its preliminary short-term application. Healthy adult dogs were prepared with a tracheostomy and with implanted electroencephalographic and nuchal electromyographic recording electrodes. A silent occlusion valve was attached to the outer end of the endotracheal tube. The electroencephalogram and electromyogram were monitored continuously by a computer that determined sleep-wake state using software developed in our laboratory. At a predetermined time (e.g., 12 s) after each sleep onset, a signal was transmitted from the computer to the valve controller, resulting in airway occlusion. When the dog aroused from sleep, the occlusion was released. These events therefore mimic those that occur in human OSA. Successful operation of the model was confirmed during 5-day continuous trials in two dogs. During the trials, the dogs became increasingly somnolent both by behavioral observation and objective measurement. The frequency of occlusions increased, and measures of apnea severity, including apnea duration and end-apneic arterial oxygen saturation, worsened. We conclude that this experimental model of repeated airway occlusion during sleep provides a potentially powerful tool for investigating the sequelae of OSA.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Obstructive sleep apnea as a cause of systemic hypertension. Evidence from a canine model.
Brooks, D., Horner, R. L., Kozar, L. F., Render-Teixeira, C. L., & Phillipson, E. A. (1997) · Journal of Clinical Investigation · doi:10.1172/jci119120 · Cited by 708
Self-citationObstructive Sleep Apnea and Cardiovascular Disease
Parish, J. M., & Somers, V. K. (2004) · Mayo Clinic Proceedings · doi:10.4065/79.8.1036 · Cited by 620
Promotion of sleep by targeting the orexin system in rats, dogs and humans
Brisbare-Roch, C., Dingemanse, J., Koberstein, R., Hoever, P., Aissaoui, H., Flores, S., Mueller, C., Nayler, O., van Gerven, J., de Haas, S. L., et al. (2007) · Nature Medicine · doi:10.1038/nm1544 · Cited by 573
Haentjens, P. (2007) · Archives of Internal Medicine · doi:10.1001/archinte.167.8.757 · Cited by 569
Selective Potentiation of Peripheral Chemoreflex Sensitivity in Obstructive Sleep Apnea
Narkiewicz, K., van de Borne, P. J. H., Pesek, C. A., Dyken, M. E., Montano, N., & Somers, V. K. (1999) · Circulation · doi:10.1161/01.cir.99.9.1183 · Cited by 560
Metadata
- Authors
- Kimoff, R. J., Makino, H., Horner, R. L., Kozar, L. F., Lue, F., Slutsky, A. S., & Phillipson, E. A.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 1994-04-01
- Volume
- 76
- Issue
- 4
- Pages
- 1810-1817
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W1872829959
- Cited by
- 78
- References
- 0
- FWCI
- 1.28
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Canine model of obstructive sleep apnea: model description and preliminary application. https://app.cochat.ai/papers/10.1152/jappl.1994.76.4.1810
- The paper
- Kimoff, R. J., Makino, H., Horner, R. L., Kozar, L. F., Lue, F., Slutsky, A. S., & Phillipson, E. A. (1994). Canine model of obstructive sleep apnea: model description and preliminary application. Journal of Applied Physiology. https://doi.org/10.1152/jappl.1994.76.4.1810
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.