Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 241

The DOI matches its Crossref record.

Distinguishing between aerobic and anaerobic appearance of dissolved CO2 in intestine during low flow

Schlichtig, R., Bowles, S. A.·1994·Journal of Applied Physiology

Abstract

Increased intestinal mucosal PCO2 is used to detect the condition of inadequate O2 delivery, i.e., “dysoxia.” However, mucosal PCO2 (PmCO2) can arise from oxidative phosphorylation, in which case it would detect metabolism that persists as blood stagnates, and/or from HCO3- neutralization by anaerobically produced metabolic acid, in which event it could represent dysoxia. We measured portal venous PCO2 (PVCO2) directly and PmCO2 indirectly with saline-filled CO2-permeable Silastic balloon tonometers in the intestinal lumen during progressive lethal cardiac tamponade in six pentobarbital-anesthetized dogs. PVCO2 and PmCO2 were relatively constant, differing by approximately 10 Torr until an O2 delivery (DO2) of approximately 1.3 ml.kg-1.min-1 was reached, below which PVCO2 and PmCO2 diverged strikingly, achieving a final difference of 78.7 +/- 35.81 (SD) Torr. To determine whether PCO2 arose from aerobic or anaerobic metabolism, we used the Dill nomogram to predict venous oxyhemoglobin (HbO2v) saturation (%HbO2v) from PVCO2. Portal venous %HbO2 predicted by the Dill nomogram agreed well with measured portal venous %HbO2 during all but the final values, indicating primarily aerobic appearance of PCO2 in venous blood, suggesting that portions of intestine that remained perfused at very low flow produced dissolved CO2 mainly by oxidative phosphorylation. As PmCO2 increased below critical DO2, however, predicted mucosal %HbO2v became strikingly negative, achieving a final value of -192 +/- 106.1%, indicating anaerobic dissolved CO2 production in mucosa. We conclude that PCO2 measured in intestinal lumen can be used to detect dysoxia.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1152/jappl.1994.76.6.2443

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 241

Metadata

Authors
Schlichtig, R., & Bowles, S. A.
Venue
Journal of Applied Physiology
Published
1994-06-01
Volume
76
Issue
6
Pages
2443-2451
ISSN
  • 0161-7567 (ISSN-L)
  • 8750-7587
  • 1522-1601
OpenAlex
W2152063232
Cited by
241
References
0
FWCI
15.23
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Distinguishing between aerobic and anaerobic appearance of dissolved CO2 in intestine during low flow. https://app.cochat.ai/papers/10.1152/jappl.1994.76.6.2443
The paper
Schlichtig, R., & Bowles, S. A. (1994). Distinguishing between aerobic and anaerobic appearance of dissolved CO2 in intestine during low flow. Journal of Applied Physiology. https://doi.org/10.1152/jappl.1994.76.6.2443

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.