No lung toxicity after repeated aerosol or intravenous delivery of plasmid-cationic liposome complexes
The DOI matches its Crossref record.
Abstract
The safety aspects of human gene therapy are of paramount importance in developing an ideal system for gene transfer. Lipofection using DNA in the form of a plasmid has been shown to successfully transfect the lungs when administered either intravenously or by aerosol. We have shown that repeated intravenous or aerosol administration of a plasmid containing the recombinant human alpha 1-antitrypsin gene and a cytomegalovirus promoter complexed to cationic liposomes results in no adverse effects on pulmonary histology, lung compliance, lung resistance, or alveolar-arterial oxygen gradient. Immunohistochemistry and Western blot analysis confirm successful gene transfer using this delivery system. We conclude that plasmids complexed to cationic liposomes may be a safe and efficacious delivery system for in vivo gene transfer to the lungs. Using this delivery system, in vivo gene therapy to the lungs can be achieved by either intravenous or aerosol administration of the transgene.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Plank, C., Mechtler, K., Szoka, F. C., & Wagner, E. (1996) · Human Gene Therapy · doi:10.1089/hum.1996.7.12-1437 · Cited by 583
Filion, M. C., & Phillips, N. C. (1997) · Biochimica et Biophysica Acta (BBA) - Biomembranes · doi:10.1016/s0005-2736(97)00126-0 · Cited by 428
Factors influencing the efficiency of cationic liposome-mediated intravenous gene delivery
Liu, Y., Mounkes, L. C., Liggitt, H. D., Brown, C. S., Solodin, I., Heath, T. D., & Debs, R. J. (1997) · Nature Biotechnology · doi:10.1038/nbt0297-167 · Cited by 405
Pulmonary Drug Delivery Systems: Recent Developments and Prospects;
Courrier, H. M., Butz, N., & Vandamme, T. F. (2002) · Critical Reviews in Therapeutic Drug Carrier Systems · doi:10.1615/critrevtherdrugcarriersyst.v19.i45.40 · Cited by 314
A novel cationic lipid greatly enhances plasmid DNA delivery and expression in mouse lung.
Wheeler, C. J., Felgner, P. L., Tsai, Y. J., Marshall, J., Sukhu, L., Doh, S. G., Hartikka, J., Nietupski, J., Manthorpe, M., Nichols, M., et al. (1996) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.93.21.11454 · Cited by 278
Metadata
- Authors
- Canonico, A. E., Plitman, J. D., Conary, J. T., Meyrick, B. O., & Brigham, K. L.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 1994-07-01
- Volume
- 77
- Issue
- 1
- Pages
- 415-419
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2271330665
- Cited by
- 103
- References
- 0
- FWCI
- 2.82
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: No lung toxicity after repeated aerosol or intravenous delivery of plasmid-cationic liposome complexes. https://app.cochat.ai/papers/10.1152/jappl.1994.77.1.415
- The paper
- Canonico, A. E., Plitman, J. D., Conary, J. T., Meyrick, B. O., & Brigham, K. L. (1994). No lung toxicity after repeated aerosol or intravenous delivery of plasmid-cationic liposome complexes. Journal of Applied Physiology. https://doi.org/10.1152/jappl.1994.77.1.415
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.