Muscle energetics and pulmonary oxygen uptake kinetics during moderate exercise
Open accessThe DOI matches its Crossref record.
Abstract
The present study tested whether, during moderate exercise, 1) the dynamic responses of ADP and changes in free energy of ATP hydrolysis (delta GATP) were similar to those of phosphocreatine [PCr; as would be expected for a simple controller of muscle respiration (QO2)] and 2) the rise in pulmonary O2 uptake (VO2) during cycle exercise would reflect the rise in muscle QO2 indicated by the calf PCr kinetics. The responses of PCr, Pi, ADP, and delta GATP were measured from the calf in five subjects during supine treadle exercise using 31P-magnetic resonance spectroscopy and compared with those for VO2, measured breath by breath during upright cycle exercise. The time constants for delta GATP [24.2 +/- 14.2 (SE) s] were not significantly different from those for PCr (26.3 +/- 17.3 s) and Pi (30.7 +/- 22.5 s) (P > 0.05). The time constants for phase 2 VO2 (29.9 +/- 16.8 s) were also similar to those of PCr. In contrast, the dynamics of ADP were distorted from those of PCr due to dynamic changes in pH. These results are consistent with mechanisms of respiratory control that feature substrate control by PCr or thermodynamic control through changes in delta GATP. However, these results are not consistent with substrate control by ADP in a simple fashion. Furthermore, the similarity of time constants for phase 2 VO2 and muscle PCr suggests that phase 2 VO2 kinetics reflect those of muscle QO2 in healthy subjects during moderate exercise.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Muscle O2 uptake kinetics in humans: implications for metabolic control
Grassi, B., Poole, D. C., Richardson, R. S., Knight, D. R., Erickson, B. K., & Wagner, P. D. (1996) · Journal of Applied Physiology · doi:10.1152/jappl.1996.80.3.988 · Cited by 561
Poole, D. C., & Jones, A. M. (2012) · Comprehensive Physiology · doi:10.1002/cphy.c100072 · Cited by 514
Muscle metabolic responses to exercise above and below the “critical power” assessed using31P-MRS
Jones, A. M., Wilkerson, D. P., DiMenna, F., Fulford, J., & Poole, D. C. (2008) · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · doi:10.1152/ajpregu.00731.2007 · Cited by 478
An Examination and Critique of Current Methods to Determine Exercise Intensity
Jamnick, N. A., Pettitt, R. W., Granata, C., Pyne, D. B., & Bishop, D. J. (2020) · Sports Medicine · doi:10.1007/s40279-020-01322-8 · Cited by 424
Rossiter, H. B., Ward, S. A., Kowalchuk, J. M., Howe, F. A., Griffiths, J. R., & Whipp, B. J. (2002) · The Journal of Physiology · doi:10.1113/jphysiol.2001.012910 · Cited by 364
Hamaoka, T., McCully, K. K., Quaresima, V., Yamamoto, K., & Chance, B. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2805437 · Cited by 329
Rossiter, H. B., Ward, S. A., Doyle, V. L., Howe, F. A., Griffiths, J. R., & Whipp, B. J. (1999) · The Journal of Physiology · doi:10.1111/j.1469-7793.1999.0921p.x · Cited by 292
Oxygen Uptake Kinetics during Exercise
Xu, F., & Rhodes, E. C. (1999) · Sports Medicine · doi:10.2165/00007256-199927050-00003 · Cited by 258
“Recently, Barstow et al.[40] compared PCr and V .”
Effects of prior heavy exercise on phase II pulmonary oxygen uptake kinetics during heavy exercise
Burnley, M., Jones, A. M., Carter, H., & Doust, J. H. (2000) · Journal of Applied Physiology · doi:10.1152/jappl.2000.89.4.1387 · Cited by 255
Interaction of factors determining oxygen uptake at the onset of exercise
Tschakovsky, M. E., & Hughson, R. L. (1999) · Journal of Applied Physiology · doi:10.1152/jappl.1999.86.4.1101 · Cited by 254
Pringle, J. S. M., Doust, J. H., Carter, H., Tolfrey, K., Campbell, I. T., & Jones, A. M. (2003) · European Journal of Applied Physiology · doi:10.1007/s00421-003-0799-1 · Cited by 216
“…UK H. Carter School of Sport Exercise and Leisure, University of Surrey Roehampton, London, SW15 3SN, UK I. T. Campbell Deparment of Anaesthesia, Wythenshawe Hospital, Southmoor Road, Manchester, M23 9LT, UK consumption in skeletal muscle to within 10% (Barstow et al. 1994; Grassi et al. 1996).”
Effects of hypoxic hypoxia on O2uptake and heart rate kinetics during heavy exercise
Engelen, M., Porszasz, J., Riley, M., Wasserman, K., Maehara, K., & Barstow, T. J. (1996) · Journal of Applied Physiology · doi:10.1152/jappl.1996.81.6.2500 · Cited by 207
Self-citationRossiter, H. B., Ward, S. A., Kowalchuk, J. M., Howe, F. A., Griffiths, J. R., & Whipp, B. J. (2001) · The Journal of Physiology · doi:10.1111/j.1469-7793.2001.0291k.x · Cited by 191
“That is, [PCr] and VO2 response profiles are generated that are more consistent with those of moderate-intensity exercise (Yoshida & Watiri, 1993; Barstow et al. 1994; McCreary et al. 1996; Rossiter et al. 1999).”
BackgroundDynamics of microvascular oxygen pressure across the rest-exercise transition in rat skeletal muscle
Behnke, B. J., Kindig, C. A., Musch, T. I., Koga, S., & Poole, D. C. (2001) · Respiration Physiology · doi:10.1016/s0034-5687(01)00195-5 · Cited by 187
(1996) · doi:10.1002/cphy.cp120118 · Cited by 113
The role of oxygen in determining phosphocreatine onset kinetics in exercising humans
Haseler, L. J., Kindig, C. A., Richardson, R. S., & Hogan, M. C. (2004) · The Journal of Physiology · doi:10.1113/jphysiol.2004.062042 · Cited by 78
“…has been demonstrated previously (Mahler, 1985; Meyer, 1988), and thus the time course of pulmonary V̇O2 onset kinetics has been related to changing [PCr] in muscle at the start of exercise (Marsh et al. 1993; Barstow et al. 1994; McCann et al. 1995; McCreary et al. 1996; Rossiter et al. 1999).”
BackgroundMethodInfluentialReliability of near-infrared spectroscopy for determining muscle oxygen saturation during exercise
Austin, K. G., Daigle, K. A., Patterson, P., Cowman, J., Chelland, S., & Haymes, E. M. (2005) · Research Quarterly for Exercise and Sport · doi:10.1080/02701367.2005.10599317 · Cited by 58
Twycross-Lewis, R., Kilduff, L. P., Wang, G., & Pitsiladis, Y. P. (2016) · Amino Acids · doi:10.1007/s00726-016-2237-9 · Cited by 36
Metadata
- Authors
- Barstow, T. J., Buchthal, S., Zanconato, S., & Cooper, D. M.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 1994-10-01
- Volume
- 77
- Issue
- 4
- Pages
- 1742-1749
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2282955701
- Cited by
- 166
- References
- 0
- FWCI
- 11.73
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.