Lung volumes during sustained microgravity on Spacelab SLS-1
The DOI matches its Crossref record.
Abstract
Gravity is known to influence the mechanical behavior of the lung and chest wall. However, the effect of sustained microgravity (mu G) on lung volumes has not been reported. Pulmonary function tests were performed by four subjects before, during, and after 9 days of mu G exposure. Ground measurements were made in standing and supine postures. Tests were performed using a bag-in-box-and-flowmeter system and a respiratory mass spectrometer. Measurements included functional residual capacity (FRC), expiratory reserve volume (ERV), residual volume (RV), inspiratory and expiratory vital capacities (IVC and EVC), and tidal volume (VT). Total lung capacity (TLC) was derived from the measured EVC and RV values. With preflight standing values as a comparison, FRC was significantly reduced by 15% (approximately 500 ml) in mu G and 32% in the supine posture. ERV was reduced by 10–20% in mu G and decreased by 64% in the supine posture. RV was significantly reduced by 18% (310 ml) in mu G but did not significantly change in the supine posture compared with standing. IVC and EVC were slightly reduced during the first 24 h of mu G but returned to 1-G standing values within 72 h of mu G exposure. IVC and EVC in the supine posture were significantly reduced by 12% compared with standing. During mu G, VT decreased by 15% (approximately 90 ml), but supine VT was unchanged compared with preflight standing values. TLC decreased by approximately 8% during mu G and in the supine posture compared with preflight standing. The reductions in FRC, ERV, and RV during mu G are probably due to the cranial shift of the diaphragm, an increase in intrathoracic blood volume, and more uniform alveolar expansion.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Cardiac Atrophy After Bed-Rest Deconditioning: A Nonneural Mechanism for Orthostatic Intolerance
Levine, B. D., Zuckerman, J. H., & Pawelczyk, J. A. (1997) · Circulation · doi:10.1161/01.cir.96.2.517 · Cited by 371
Human Pathophysiological Adaptations to the Space Environment
Demontis, G. C., Germani, M. M., Caiani, E. G., Barravecchia, I., Passino, C., & Angeloni, D. (2017) · Frontiers in Physiology · doi:10.3389/fphys.2017.00547 · Cited by 354
Human Health during Space Travel: State-of-the-Art Review
Krittanawong, C., Singh, N. K., Scheuring, R. A., Urquieta, E., Bershad, E. M., Macaulay, T. R., Kaplin, S., Dunn, C., Kry, S. F., Russomano, T., et al. (2022) · Cells · doi:10.3390/cells12010040 · Cited by 170
“During the Spacelab Life Sciences-1 mission, microgravity exposure resulted in 10%, 15%, 10–20%, and 18% reductions in VC, FRC, expiratory reserve volume (ERV), and residual volume (RV), respectively, compared to values seen in Earth’s gravity [227].”
BackgroundBaevsky, R. M., Baranov, V. M., Funtova, I. I., Diedrich, A., Pashenko, A. V., Chernikova, A. G., Drescher, J., Jordan, J., & Tank, J. (2007) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00137.2007 · Cited by 158
“Lung volumes were found to be reduced during short-term spaceflight (16).”
BackgroundPhysiological, Pharmacokinetic, and Pharmacodynamic Changes in Space
Graebe, A., Schuck, E. L., Lensing, P., Putcha, L., & Derendorf, H. (2004) · The Journal of Clinical Pharmacology · doi:10.1177/0091270004267193 · Cited by 113
Human Response to Space Flight
Baker, E. S., Barratt, M. R., & Wear, M. L. (2008) · Principles of Clinical Medicine for Space Flight · doi:10.1007/978-0-387-68164-1_2 · Cited by 41
“to normal later inflight, n = 4 [36] Residual volume ↓ about18% c/w preflight standing, n = 4 [62]”
BackgroundInfluential
Metadata
- Authors
- Elliott, A. R., Prisk, G. K., Guy, H. J., & West, J. B.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 1994-10-01
- Volume
- 77
- Issue
- 4
- Pages
- 2005-2014
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W1800867352
- Cited by
- 107
- References
- 0
- FWCI
- 2.56
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.