Skin of the dorsal aspect of human hands and fingers possesses an active vasodilator system
The DOI matches its Crossref record.
Abstract
To test for an active vasodilator system in human hand and finger skin, seven subjects had a small area of dorsal hand, palm, or dorsal finger pretreated with bretylium (BT) to block adrenergic vasoconstriction. Skin blood flow was monitored at a BT-treated site, a comparable untreated site, and the forearm by laser-Doppler flowmetry. Cutaneous vascular conductance (CVC) was evaluated from the ratio of blood flow to arterial pressure. Body cooling, to evaluate vasoconstrictor system blockade, caused CVC at untreated sites of forearm, palm, dorsal hand, and dorsal finger to fall by 45 +/- 4, 85 +/- 5, 51 +/- 9, and 63 +/- 7%, respectively (all P < 0.05). At BT-treated sites of palm, dorsal hand, and dorsal finger, reductions in CVC were only 13 +/- 3, 2 +/- 18, and 13 +/- 4%, respectively (dorsal hand not significant, others P < 0.05). With body heating, increases in CVC at untreated sites of forearm, palm, dorsal hand, and dorsal finger were 881 +/- 165, 779 +/- 368, 423 +/- 115, and 1,430 +/- 716%, respectively (all P < 0.05). At BT-treated sites of palm, dorsal hand, and dorsal finger, increases were 35 +/- 15, 342 +/- 107, and 343 +/- 34%, respectively (palm not significant, others P < 0.05). Increased CVC at the palm began after 1.2 +/- 0.2 min of heating, significantly earlier than forearm (11.8 +/- 2.5 min), dorsal hand (16.4 +/- 3.4 min), or dorsal finger (15.6 +/- 3.6 min), which did not differ significantly from one another.(ABSTRACT TRUNCATED AT 250 WORDS)
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Skin blood flow in adult human thermoregulation: How it works, when it does not, and why
Charkoudian, N. (2003) · Mayo Clinic Proceedings · doi:10.4065/78.5.603 · Cited by 1,041
“(dorsal aspect),[28] which can limit data interpretation, depending on the issues being addressed.”
BackgroundRecent advances in thermoregulation
Tansey, E. A., & Johnson, C. D. (2015) · Advances in Physiology Education · doi:10.1152/advan.00126.2014 · Cited by 527
Cutaneous Vasodilator and Vasoconstrictor Mechanisms in Temperature Regulation
Johnson, J. M., Minson, C. T., & Kellogg, D. L. (2014) · Comprehensive Physiology · doi:10.1002/cphy.c130015 · Cited by 414
Self-citationNitric oxide and cutaneous active vasodilation during heat stress in humans
Kellogg, D. L., Crandall, C. G., Liu, Y., Charkoudian, N., & Johnson, J. M. (1998) · Journal of Applied Physiology · doi:10.1152/jappl.1998.85.3.824 · Cited by 312
Self-citationCardiovascular Adjustments to Heat Stress
Johnson, J. M., & Proppe, D. W. (1996) · Comprehensive Physiology · doi:10.1002/cphy.cp040111 · Cited by 291
Self-citation
Metadata
- Authors
- Johnson, J. M., Pergola, P. E., Liao, F. K., Kellogg, D. L., & Crandall, C. G.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 1995-03-01
- Volume
- 78
- Issue
- 3
- Pages
- 948-954
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2403447213
- Cited by
- 99
- References
- 0
- FWCI
- 1.27
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Skin of the dorsal aspect of human hands and fingers possesses an active vasodilator system. https://app.cochat.ai/papers/10.1152/jappl.1995.78.3.948
- The paper
- Johnson, J. M., Pergola, P. E., Liao, F. K., Kellogg, D. L., & Crandall, C. G. (1995). Skin of the dorsal aspect of human hands and fingers possesses an active vasodilator system. Journal of Applied Physiology. https://doi.org/10.1152/jappl.1995.78.3.948
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.