Limitations of the efficacy of hemoglobin-based oxygen-carrying solutions
The DOI matches its Crossref record.
Abstract
Improvements in hemoglobin-based oxygen-carrying (HBOCs) solutions have overcome the toxicities that plagued earlier efforts. However, limitations of the efficacy of HBOCs are emerging. The potential limitations of an HBOC were studied in an ovine model (n = 6) of exchange transfusion. Hemodynamic, oxygen transport, and hemoglobin kinetic parameters were examined during isovolumic blood exchange to a final hematocrit of 3.2 +/- 0.7% and a plasma hemoglobin concentration of 8.1 +/- 0.4 g/dl while sheep were awake and breathing room air. However, the infusion of HBOC was associated with immediate increases in systemic and pulmonary arterial pressures. Despite hemodilution with HBOC, systemic and pulmonary vascular resistance increased 43.9% (P < 0.001) and 204.2% (P < 0.001), respectively, after HBOC infusion. After blood exchange, the plasma hemoglobin level exhibited a circulatory half-life of 52.7 +/- 18.0 h. The formation of methemoglobin was significant, accounting for 33.0 +/- 7.1% of the total circulating plasma hemoglobin at 24 h; the half-life of HBOC capable of carrying oxygen was 30.1 +/- 5.4 h. This relatively short period of oxygen-carrying efficacy and the observed vasoconstriction properties may constrain the potential applications of HBOC solutions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Rother, R. P., Bell, L., Hillmen, P., & Gladwin, M. T. (2005) · JAMA · doi:10.1001/jama.293.13.1653 · Cited by 1,557
Cell-free hemoglobin limits nitric oxide bioavailability in sickle-cell disease
Reiter, C. D., Wang, X., Tanus-Santos, J. E., Hogg, N., Cannon, R. O., Schechter, A. N., & Gladwin, M. T. (2002) · Nature Medicine · doi:10.1038/nm1202-799 · Cited by 1,330
Riess, J. G. (2001) · Chemical Reviews · doi:10.1021/cr970143c · Cited by 773
Donadee, C., Raat, N. J. H., Kanias, T., Tejero, J., Lee, J. S., Kelley, E. E., Zhao, X., Liu, C., Reynolds, H., Azarov, I., et al. (2011) · Circulation · doi:10.1161/circulationaha.110.008698 · Cited by 572
Rate of reaction with nitric oxide determines the hypertensive effect of cell-free hemoglobin
Doherty, D. H., Doyle, M. P., Curry, S. R., Vali, R. J., Fattor, T. J., Olson, J. S., & Lemon, D. D. (1998) · Nature Biotechnology · doi:10.1038/nbt0798-672 · Cited by 432
Metadata
- Authors
- Lee, R., Neya, K., Svizzero, T. A., & Vlahakes, G. J.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 1995-07-01
- Volume
- 79
- Issue
- 1
- Pages
- 236-242
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W1919712442
- Cited by
- 148
- References
- 0
- FWCI
- 3.41
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Limitations of the efficacy of hemoglobin-based oxygen-carrying solutions. https://app.cochat.ai/papers/10.1152/jappl.1995.79.1.236
- The paper
- Lee, R., Neya, K., Svizzero, T. A., & Vlahakes, G. J. (1995). Limitations of the efficacy of hemoglobin-based oxygen-carrying solutions. Journal of Applied Physiology. https://doi.org/10.1152/jappl.1995.79.1.236
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.