Effect of negative intrathoracic pressure on left ventricular pressure dynamics and relaxation
The DOI matches its Crossref record.
Abstract
To investigate the effect of a fall of intrathoracic pressure on left ventricular (LV) hemodynamics and relaxation, simultaneous micromanometric recordings of LV and aortic pressures were performed at rest and during two graded Mueller maneuvers in 16 patients undergoing cardiac catheterization for aortic valve stenosis (n = 8) or chest pain (n = 8). The reductions (means +/- SE) of airway pressure during the lesser and greater maneuvers were 26 +/- 1 and 42 +/- 1 mmHg, respectively. Simultaneously, LV isovolumic-developed pressure increased by 9 +/- 3 and 21 +/- 4 mmHg, respectively (P < 0.03 for both). During the greater maneuver, the individual changes of the time constant of LV isovolumic relaxation (tau) correlated with the changes of LV isovolumic-developed pressure (r = 0.73; P = 0.002). In patients with a > 20-mmHg rise in isovolumic-developed pressure, tau increased by 10.3 +/- 4.6 ms. By multiple-regression analysis, the change of tau was related directly to the change of isovolumic-developed pressure (standardized coefficient beta = 0.80; P = 0.001) and inversely related to the resting systolic LV-aortic pressure gradient (beta = -0.37; P = 0.050). The other hemodynamic changes were independent of aortic valve stenosis. In conclusion, during the Mueller maneuver, the LV isovolumic contraction load increases and tau lengthens, particularly with higher elevations of LV systolic load.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Obstructive Sleep Apnea: Implications for Cardiac and Vascular Disease
Shamsuzzaman, A. S. M., Gersh, B. J., & Somers, V. K. (2003) · JAMA · doi:10.1001/jama.290.14.1906 · Cited by 1,188
Day–Night Pattern of Sudden Death in Obstructive Sleep Apnea
Gami, A. S., Howard, D. E., Olson, E. J., & Somers, V. K. (2005) · New England Journal of Medicine · doi:10.1056/nejmoa041832 · Cited by 1,032
Sleep Apnea and Cardiovascular Disease
LEUNG, R. S. T., & DOUGLAS BRADLEY, T. (2001) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.164.12.2107045 · Cited by 649
Arias, M. A., García-Río, F., Alonso-Fernández, A., Mediano, O., Martínez, I., & Villamor, J. (2005) · Circulation · doi:10.1161/circulationaha.104.501841 · Cited by 420
Obstructive sleep apnea and cardiovascular disease
Lattimore, J. O.-D. L., Celermajer, D. S., & Wilcox, I. (2003) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(03)00184-0 · Cited by 359
Metadata
- Authors
- Virolainen, J., Ventila, M., Turto, H., & Kupari, M.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 1995-08-01
- Volume
- 79
- Issue
- 2
- Pages
- 455-460
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W1952768801
- Cited by
- 104
- References
- 0
- FWCI
- 1.18
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Effect of negative intrathoracic pressure on left ventricular pressure dynamics and relaxation. https://app.cochat.ai/papers/10.1152/jappl.1995.79.2.455
- The paper
- Virolainen, J., Ventila, M., Turto, H., & Kupari, M. (1995). Effect of negative intrathoracic pressure on left ventricular pressure dynamics and relaxation. Journal of Applied Physiology. https://doi.org/10.1152/jappl.1995.79.2.455
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.