Near-infrared estimation of O2 supply and consumption in forearm muscles working at varying intensity
The DOI matches its Crossref record.
Abstract
We estimated a blood flow index, O2 supply index, and O2 consumption index from near-infrared (NIR) signals during venous occlusion imposed at rest and immediately after handgrip exercise with loads equal to 5, 10, 15, 20, 25, and 30% of the maximum voluntary contraction. We also estimated forearm blood flow (BFfa) by strain-gauge plethysmography and forearm O2 consumption (VO2fa) by the invasive method. There was a significant correlation between the rate of increase in total hemoglobin during venous occlusion obtained from NIR signals and BFfa in each subject (r = 0.853 approximately 0.981, P < 0.001). There was also a significant correlation (r = 0.854 approximately 0.944, P < 0.001) between the O2 consumption index estimated from NIR signals and VO2fa. The mean values for O2 supply index in five subjects increased with exercise intensity, while the O2 consumption index showed no further increase about 25% of maximum voluntary contraction. We found significant positive correlations between the O2 supply index and BFfa (r = 0.986, P < 0.001) and the O2 consumption index and VO2fa (r = 0.976, P < 0.001) during exercise at 5-30% of maximum voluntary contraction. These results demonstrate that analysis of NIR signals during venous occlusion provides an advantageous method of estimation of O2 supply and consumption in working muscles during exercise of varying intensity.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Principles, Techniques, and Limitations of Near Infrared Spectroscopy
Ferrari, M., Mottola, L., & Quaresima, V. (2004) · Canadian Journal of Applied Physiology · doi:10.1139/h04-031 · Cited by 997
Understanding near infrared spectroscopy and its application to skeletal muscle research
Barstow, T. J. (2019) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00166.2018 · Cited by 470
Van Beekvelt, M. C. P., Colier, W. N. J. M., Wevers, R. A., & Van Engelen, B. G. M. (2001) · Journal of Applied Physiology · doi:10.1152/jappl.2001.90.2.511 · Cited by 430
Adipose tissue thickness affects in vivo quantitative near-IR spectroscopy in human skeletal muscle
VAN BEEKVELT, M. C. P., BORGHUIS, M. S., VAN ENGELEN, B. G. M., WEVERS, R. A., & COLIER, W. N. J. M. (2001) · Clinical Science · doi:10.1042/cs1010021 · Cited by 369
Hamaoka, T., McCully, K. K., Quaresima, V., Yamamoto, K., & Chance, B. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2805437 · Cited by 329
“NIRS-determined measures of mBF and mVO2 by the venous occlusion method have been shown to agree with traditional measurements using plethysmography(114,129) and the Fick method.(114,116,129) The advantage of NIRS is that it is capable”
MethodFantini, S., Hueber, D., Franceschini, M. A., Gratton, E., Rosenfeld, W., Stubblefield, P. G., Maulik, D., & Stankovic, M. R. (1999) · Physics in Medicine and Biology · doi:10.1088/0031-9155/44/6/308 · Cited by 277
Oxidative metabolism in muscle
Ferrari, M., Binzoni, T., & Quaresima, V. (1997) · Philosophical Transactions of the Royal Society of London. Series B: Biological Sciences · doi:10.1098/rstb.1997.0049 · Cited by 247
“In addition, with some simple physiological manoeuvres, it is possible to quantify muscle VO # (Cheatle et al. 1991; De Blasi et al. 1993), flow (Edwards et al. 1993; De Blasi et al. 1994; Homma et al. 1996a) and venous saturation (Yoxall & Weindling 1996, 1997).”
BackgroundMethodInfluentialYu, G., Durduran, T., Lech, G., Zhou, C., Chance, B., Mohler, E. R., & Yodh, A. G. (2005) · Journal of Biomedical Optics · doi:10.1117/1.1884603 · Cited by 230
Gómez, H., Torres, A., Polanco, P., Kim, H. K., Zenker, S., Puyana, J. C., & Pinsky, M. R. (2008) · Intensive Care Medicine · doi:10.1007/s00134-008-1145-1 · Cited by 206
Homma, S., Fukunaga, T., & Kagaya, A. (1996) · Journal of Biomedical Optics · doi:10.1117/12.252417 · Cited by 123
Self-citationGurley, K., Shang, Y., & Yu, G. (2012) · Journal of Biomedical Optics · doi:10.1117/1.jbo.17.7.075010 · Cited by 81
Metadata
- Authors
- Homma, S., Eda, H., Ogasawara, S., & Kagaya, A.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 1996-04-01
- Volume
- 80
- Issue
- 4
- Pages
- 1279-1284
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2186645054
- Cited by
- 123
- References
- 0
- FWCI
- 12.05
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.