Kinetics of pulmonary oxygen uptake and muscle phosphates during moderate-intensity calf exercise
The DOI matches its Crossref record.
Abstract
The purpose of this study is to directly compare the dynamic responses of phosphocreatine (PCr) and P(i) to those oxygen uptake (VO2) measured at the lung during transitions to and from moderate-intensity exercise. Changes in PCr and P(i) were measured by 31P-nuclear magnetic resonance spectroscopy, and changes in VO2 were measured breath by breath by mass spectroscopy during transitions to and from moderate-intensity square-wave ankle plantar flexion exercise in 11 subjects (7 men and 4 women; mean age 27 yr). Three repeated transitions were averaged for improvement in signal-to-noise ratio of phosphate data, and 12 transitions were averaged for VO2 measurements. Averaged transitions were fit with a monoexponential curve for determination of the time constant (tau) of the responses. Mean tau values for on transients of PCr, P(i), and phrase 2 VO2 were 47.0, 57.7, and 44.5 s, respectively, whereas means tau values for off transients were 44.8, 42.1, and 33.4 s, respectively. There were no significant differences between tau values for phosphate- and VO2-measured transients or on and off transients. The similarity of on and off kinetics supports linear first-order respiratory control models. Measurement of phase 2 pulmonary VO2 kinetics to and from moderate-intensity small-muscle-mass exercise reflect muscle phosphate kinetics (and muscle oxygen consumption).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Poole, D. C., & Jones, A. M. (2012) · Comprehensive Physiology · doi:10.1002/cphy.c100072 · Cited by 514
Oxidative phosphorylation: regulation and role in cellular and tissue metabolism
Wilson, D. F. (2017) · The Journal of Physiology · doi:10.1113/jp273839 · Cited by 377
“This reaction is near equilibrium (Lawson & Veech, 1978) and 31P NMR can be used to measure the concentrations of some of the important metabolites in energy metabolism (ATP, CrP and Pi) non-invasively and in real time (Hogan et al. 1983, 1992; Kawano et al. 1988; McCully et al. 1989; McAllister & Terjung, 1991; Marsh…”
BackgroundDeLorey, D. S., Kowalchuk, J. M., & Paterson, D. H. (2003) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00956.2002 · Cited by 369
Self-citationSkeletal muscle phosphocreatine recovery in exercise-trained humans is dependent on O2availability
Haseler, L. J., Hogan, M. C., & Richardson, R. S. (1999) · Journal of Applied Physiology · doi:10.1152/jappl.1999.86.6.2013 · Cited by 326
Rossiter, H. B., Ward, S. A., Doyle, V. L., Howe, F. A., Griffiths, J. R., & Whipp, B. J. (1999) · The Journal of Physiology · doi:10.1111/j.1469-7793.1999.0921p.x · Cited by 292
Oxygen Uptake Kinetics during Exercise
Xu, F., & Rhodes, E. C. (1999) · Sports Medicine · doi:10.2165/00007256-199927050-00003 · Cited by 258
“, [41] for example, participants performed 12 square-wave repetitions over 4 to 5 sessions.”
InfluentialLarge energetic adaptations of elderly muscle to resistance and endurance training
Jubrias, S. A., Esselman, P. C., Price, L. B., Cress, M. E., & Conley, K. E. (2001) · Journal of Applied Physiology · doi:10.1152/jappl.2001.90.5.1663 · Cited by 213
“In humans, kPCr is proportional to oxidative enzyme activity (41) and correlates with muscle O2 uptake and whole body pulmonary O2 uptake for the quadriceps (46) and plantar flexors (40).”
BackgroundRossiter, H. B., Ward, S. A., Kowalchuk, J. M., Howe, F. A., Griffiths, J. R., & Whipp, B. J. (2001) · The Journal of Physiology · doi:10.1111/j.1469-7793.2001.0291k.x · Cited by 191
“That is, [PCr] and VO2 response profiles are generated that are more consistent with those of moderate-intensity exercise (Yoshida & Watiri, 1993; Barstow et al. 1994; McCreary et al. 1996; Rossiter et al. 1999).”
BackgroundThe role of oxygen in determining phosphocreatine onset kinetics in exercising humans
Haseler, L. J., Kindig, C. A., Richardson, R. S., & Hogan, M. C. (2004) · The Journal of Physiology · doi:10.1113/jphysiol.2004.062042 · Cited by 78
“…has been demonstrated previously (Mahler, 1985; Meyer, 1988), and thus the time course of pulmonary V̇O2 onset kinetics has been related to changing [PCr] in muscle at the start of exercise (Marsh et al. 1993; Barstow et al. 1994; McCann et al. 1995; McCreary et al. 1996; Rossiter et al. 1999).”
BackgroundMethodInfluentialTwycross-Lewis, R., Kilduff, L. P., Wang, G., & Pitsiladis, Y. P. (2016) · Amino Acids · doi:10.1007/s00726-016-2237-9 · Cited by 36
Metadata
- Authors
- McCreary, C. R., Chilibeck, P. D., Marsh, G. D., Paterson, D. H., Cunningham, D. A., & Thompson, R. T.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 1996-09-01
- Volume
- 81
- Issue
- 3
- Pages
- 1331-1338
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2298674995
- Cited by
- 115
- References
- 0
- FWCI
- 11.04
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.