CoChat

Alignment of microvascular units along skeletal muscle fibers of hamster retractor

Emerson, Geoffrey G., Segal, Steven S. · 1997 · Journal of Applied Physiology
Cited by 54

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Emerson, Geoffrey G., and Steven S. Segal. Alignment of microvascular units along skeletal muscle fibers of hamster retractor. J. Appl. Physiol. 82(1): 42–48, 1997.—When muscle fibers contract, blood flow requirements increase along their entire length. However, the organization of capillary perfusion along muscle fibers is unclear. The microvascular unit (MVU) is defined as a terminal arteriole and the group of capillaries it supplies. We investigated whether neighboring MVUs along the fiber axis perfused the same group of muscle fibers by using the parallel-fibered retractor muscle. Hamsters were anesthetized and perfused with Microfil to visualize MVUs relative to muscle fibers. Fields of study, which encompassed five to seven neighboring MVUs along a muscle fiber, were chosen from the interior of muscles and along muscle edges. On average, MVUs were 1 mm in length, 0.50 mm in width, and 0.1 mm deep; segments of ∼30 fibers were contained in this tissue volume of 0.05 mm 3 (20 MVUs/mg muscle). The total distance across muscle fibers encompassed by a pair of MVUs is designated “union” (U); the fraction of this distance common to both MVUs is designated “intersection” (I). The ratio of I to U for the widths of neighboring MVUs provides an index of MVU alignment along muscle fibers (e.g., I/U = 1.0 indicates complete alignment, where the fibers perfused by one MVU are the same as those perfused by the neighboring MVU). We found that I/U along muscle edges (0.71 ± 0.02) was greater ( P < 0.05) than the ratio measured within muscles (0.66 ± 0.02). A model predicted a maximum I/U of 0.58 with random MVU alignment. Thus measured values were closer to random than to complete alignment. These findings indicate that an increase in blood flow along muscle fibers requires the perfusion of many MVUs and imply that vasodilation is coordinated among the parent arterioles from which corresponding MVUs arise.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1152/jappl.1997.82.1.42

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 54

Metadata

Authors
Emerson, G. G., & Segal, S. S.
Venue
Journal of Applied Physiology
Published
1997-01-01
Volume
82
Issue
1
Pages
42-48
ISSN
  • 0161-7567 (ISSN-L)
  • 8750-7587
  • 1522-1601
OpenAlex
W2162610977
Cited by
54
References
1
FWCI
4.22
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.