The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Cardiac output estimated noninvasively from oxygen uptake during exercise
Open accessAbstract
Stringer, William W., James E. Hansen, and K. Wasserman.Cardiac output estimated noninvasively from oxygen uptake during exercise. J. Appl. Physiol. 82(3): 908–912, 1997.—Because gas-exchange measurements during cardiopulmonary exercise testing allow noninvasive measurement of oxygen uptake (V˙o 2), which is equal to cardiac output (CO) × arteriovenous oxygen content difference [C(a-[Formula: see text])], CO and stroke volume could theoretically be estimated if the C(a-[Formula: see text]) increased in a predictable fashion as a function of %maximumV˙o 2(V˙o 2 max) during exercise. To investigate the behavior of C(a-[Formula: see text]) during progressively increasing ramp pattern cycle ergometry exercise, 5 healthy subjects performed 10 studies to exhaustion while arterial and mixed venous blood were sampled. Samples were analyzed for blood gases (pH, [Formula: see text],[Formula: see text]) and oxyhemoglobin and hemoglobin concentration with a CO-oximeter. The C(a-[Formula: see text]) (ml/100 ml) could be estimated with a linear regression [C(a-[Formula: see text]) = 5.72 + 0.105 × %V˙o 2 max; r = 0.94]. The CO estimated from the C(a-[Formula: see text]) by using the above linear regression was well correlated with the CO determined by the direct Fick method ( r = 0.96). The coefficient of variation of the estimated CO was small (7–9%) between the lactic acidosis threshold and peakV˙o 2. The behavior of C(a-[Formula: see text]), as related to peakV˙o 2, was similar regardless of cardiac function compared with similar measurements from studies in the literature performed in normal and congestive heart failure patients. In summary, CO and stroke volume can be estimated during progressive work rate exercise testing from measuredV˙o 2 (in normal subjects and patients with congestive heart failure), and the resultant linear regression equation provides a good estimate of C(a-[Formula: see text]).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A new method for detecting anaerobic threshold by gas exchange
Beaver, W. L., Wasserman, K., & Whipp, B. J. (1986) · Journal of Applied Physiology · doi:10.1152/jappl.1986.60.6.2020 · Cited by 4,103
Self-citationCatheter Replacement of the Needle in Percutaneous Arteriography: A new technique
Seldinger, S. I. (1953) · Acta Radiologica · doi:10.3109/00016925309136722 · Cited by 3,270
A new technique for measurement of cardiac output by thermodilution in man
Ganz, W., Donoso, R., Marcus, H. S., Forrester, J. S., & Swan, H. J. C. (1971) · The American Journal of Cardiology · doi:10.1016/0002-9149(71)90436-x · Cited by 763
Sullivan, M. J., Knight, J. D., Higginbotham, M. B., & Cobb, F. R. (1989) · Circulation · doi:10.1161/01.cir.80.4.769 · Cited by 519
Cardiopulmonary exercise testing for evaluation of chronic cardiac failure
Weber, K. T., & Janicki, J. S. (1985) · The American Journal of Cardiology · doi:10.1016/0002-9149(85)90792-1 · Cited by 374
Metabolic Acidosis during Exercise in Patients with Chronic Obstructive Pulmonary Disease
Sue, D. Y., Wasserman, K., Moricca, R. B., & Casaburi, R. (1988) · Chest · doi:10.1378/chest.94.5.931 · Cited by 354
Self-citationDetermination of Mixed Venous CO2 Tensions by Rebreathing
Collier, C. R. (1956) · Journal of Applied Physiology · doi:10.1152/jappl.1956.9.1.25 · Cited by 275
Determination of PvCOCO2 From the Exponential CO2 Rise During Rebreathing
Defares, J. G. (1958) · Journal of Applied Physiology · doi:10.1152/jappl.1958.13.2.159 · Cited by 167
Fishman, A. P., & Richards, D. W. (1982) · Springer eBooks · doi:10.1007/978-1-4614-7546-0_2 · Cited by 59
Cited by
ATS/ACCP statement on cardiopulmonary exercise testing
(2003) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.167.2.211 · Cited by 3,026
ATS/ACCP statement on cardiopulmonary exercise testing
Ross, R. M. (2003) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.167.10.950 · Cited by 2,073
Balady, G. J., Arena, R., Sietsema, K., Myers, J., Coke, L., Fletcher, G. F., Forman, D., Franklin, B., Guazzi, M., Gulati, M., et al. (2010) · Circulation · doi:10.1161/cir.0b013e3181e52e69 · Cited by 1,964
Exercise Pathophysiology in Patients With Primary Pulmonary Hypertension
Sun, X.-G., Hansen, J. E., Oudiz, R. J., & Wasserman, K. (2001) · Circulation · doi:10.1161/hc2901.093198 · Cited by 623
Self-citationÖzyener, F., Rossiter, H. B., Ward, S. A., & Whipp, B. J. (2001) · The Journal of Physiology · doi:10.1111/j.1469-7793.2001.t01-1-00891.x · Cited by 459
Metadata
- Authors
- Stringer, W. W., Hansen, J. E., & Wasserman, K.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 1997-03-01
- Volume
- 82
- Issue
- 3
- Pages
- 908-912
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2163302402
- Cited by
- 282
- References
- 9
- FWCI
- 8.45
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Cardiac output estimated noninvasively from oxygen uptake during exercise. https://app.cochat.ai/papers/10.1152/jappl.1997.82.3.908
- The paper
- Stringer, W. W., Hansen, J. E., & Wasserman, K. (1997). Cardiac output estimated noninvasively from oxygen uptake during exercise. Journal of Applied Physiology. https://doi.org/10.1152/jappl.1997.82.3.908
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.