The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Diaphragm thickening during inspiration
Abstract
Cohn, David, Joshua O. Benditt, Scott Eveloff, and F. Dennis McCool. Diaphragm thickening during inspiration. J. Appl. Physiol. 83(1): 291–296, 1997.—Ultrasound has been used to measure diaphragm thickness ( T di) in the area where the diaphragm abuts the rib cage (zone of apposition). However, the degree of diaphragm thickening during inspiration reported as obtained by one-dimensional M-mode ultrasound was greater than that predicted by using other radiographic techniques. Because two-dimensional (2-D) ultrasound provides greater anatomic definition of the diaphragm and neighboring structures, we used this technique to reevaluate the relationship between lung volume and T di. We first established the accuracy and reproducibility of 2-D ultrasound by measuring T di with a 7.5-MHz transducer in 26 cadavers. We found that T di measured by ultrasound correlated significantly with that measured by ruler ( R 2 = 0.89), with the slope of this relationship approximating a line of identity ( y = 0.89 x + 0.04 mm). The relationship between lung volume and T di was then studied in nine subjects by obtaining diaphragm images at the five target lung volumes [25% increments from residual volume (RV) to total lung capacity (TLC)]. Plots of T di vs. lung volume demonstrated that the diaphragm thickened as lung volume increased, with a more rapid rate of thickening at the higher lung volumes [ T di = 1.74 vital capacity (VC)2 + 0.26 VC + 2.7 mm] ( R 2= 0.99; P < 0.001) where lung volume is expressed as a fraction of VC. The mean increase in T di between RV and TLC for the group was 54% (range 42–78%). We conclude that 2-D ultrasound can accurately measure T di and that the average thickening of the diaphragm when a subject is inhaling from RV to TLC using this technique is in the range of what would be predicted from a 35% shortening of the diaphragm.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Effect of body weight and muscularity on human diaphragm muscle mass, thickness, and area
Arora, N. S., & Rochester, D. F. (1982) · Journal of Applied Physiology · doi:10.1152/jappl.1982.52.1.64 · Cited by 381
Diaphragmatic thickness-lung volume relationship in vivo
Wait, J. L., Nahormek, P. A., Yost, W. T., & Rochester, D. P. (1989) · Journal of Applied Physiology · doi:10.1152/jappl.1989.67.4.1560 · Cited by 204
Three-dimensional reconstruction of the in vivo human diaphragm shape at different lung volumes
Gauthier, A. P., Verbanck, S., Estenne, M., Segebarth, C., Macklem, P. T., & Paiva, M. (1994) · Journal of Applied Physiology · doi:10.1152/jappl.1994.76.2.495 · Cited by 193
Force-length relationship of the normal human diaphragm
Braun, N. M., Arora, N. S., & Rochester, D. F. (1982) · Journal of Applied Physiology · doi:10.1152/jappl.1982.53.2.405 · Cited by 192
Variability of Diaphragm Structure Among Healthy Individuals
McCool, F. D., Benditt, J. O., Conomos, P., Anderson, L., Sherman, C. B., & Hoppin, F. G. (1997) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.155.4.9105074 · Cited by 81
Self-citationDependence of diaphragmatic length on lung volume and thoracoabdominal configuration
Loring, S. H., Mead, J., & Griscom, N. T. (1985) · Journal of Applied Physiology · doi:10.1152/jappl.1985.59.6.1961 · Cited by 64
Contractile characteristics and operating lengths of canine neck inspiratory muscles
Farkas, G. A., & Rochester, D. F. (1986) · Journal of Applied Physiology · doi:10.1152/jappl.1986.61.1.220 · Cited by 35
Cited by
ERS statement on respiratory muscle testing at rest and during exercise
Laveneziana, P., Albuquerque, A., Aliverti, A., Babb, T., Barreiro, E., Dres, M., Dubé, B.-P., Fauroux, B., Gea, J., Guenette, J. A., et al. (2019) · European Respiratory Journal · doi:10.1183/13993003.01214-2018 · Cited by 818
Evolution of Diaphragm Thickness during Mechanical Ventilation. Impact of Inspiratory Effort
Goligher, E. C., Fan, E., Herridge, M. S., Murray, A., Vorona, S., Brace, D., Rittayamai, N., Lanys, A., Tomlinson, G., Singh, J. M., et al. (2015) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201503-0620oc · Cited by 608
Matamis, D., Soilemezi, E., Tsagourias, M., Akoumianaki, E., Dimassi, S., Boroli, F., Richard, J.-C. M., & Brochard, L. (2013) · Intensive Care Medicine · doi:10.1007/s00134-013-2823-1 · Cited by 576
McCool, F. D., & Tzelepis, G. E. (2012) · New England Journal of Medicine · doi:10.1056/nejmra1007236 · Cited by 489
Self-citationDiaphragm ultrasound as a predictor of successful extubation from mechanical ventilation
DiNino, E., Gartman, E. J., Sethi, J. M., & McCool, F. D. (2014) · Thorax · doi:10.1136/thoraxjnl-2013-204111 · Cited by 487
Self-citation
Metadata
- Authors
- Cohn, D., Benditt, J. O., Eveloff, S., & McCool, F. D.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 1997-07-01
- Volume
- 83
- Issue
- 1
- Pages
- 291-296
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2122724909
- Cited by
- 257
- References
- 7
- FWCI
- 1.34
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.