The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Ultrasound Doppler estimates of femoral artery blood flow during dynamic knee extensor exercise in humans
Abstract
Rådegran, G. Ultrasound Doppler estimates of femoral artery blood flow during dynamic knee extensor exercise in humans. J. Appl. Physiol.83(4): 1383–1388, 1997.—Ultrasound Doppler has been used to measure arterial inflow to a human limb during intermittent static contractions. The technique, however, has neither been thoroughly validated nor used during dynamic exercise. In this study, the inherent problems of the technique have been addressed, and the accuracy was improved by storing the velocity tracings continuously and calculating the flow in relation to the muscle contraction-relaxation phases. The femoral arterial diameter measurements were reproducible with a mean coefficient of variation within the subjects of 1.2 ± 0.2%. The diameter was the same whether the probe was fixed or repositioned at rest (10.8 ± 0.2 mm) or measured during dynamic exercise. The blood velocity was sampled over the width of the diameter and the parabolic velocity profile, since sampling in the center resulted in an overestimation by 22.6 ± 9.1% ( P< 0.02). The femoral arterial Doppler blood flow increased linearly ( r = 0.997, P < 0.001) with increasing load [Doppler blood flow = 0.080 ⋅ load (W) + 1.446 l/min] and was correlated positively with simultaneous thermodilution venous outflow measurements ( r = 0.996, P < 0.001). The two techniques were linearly related (Doppler = thermodilution ⋅ 0.985 + 0.071 l/min; r = 0.996, P < 0.001), with a coefficient of variation of ∼6% for both methods.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Maximal perfusion of skeletal muscle in man.
Andersen, P., & Saltin, B. (1985) · The Journal of Physiology · doi:10.1113/jphysiol.1985.sp015794 · Cited by 1,250
Measurement of blood flow by ultrasound: Accuracy and sources of error
Gill, R. W. (1985) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(85)90035-3 · Cited by 765
Dynamic knee extension as model for study of isolated exercising muscle in humans
Andersen, P., Adams, R. P., Sjogaard, G., Thorboe, A., & Saltin, B. (1985) · Journal of Applied Physiology · doi:10.1152/jappl.1985.59.5.1647 · Cited by 384
Leg Blood Flow during Exercise in Man
Jorfeldt, L., & Wahren, J. (1971) · Clinical Science · doi:10.1042/cs0410459 · Cited by 362
Hemodynamic adaptations to exercise
Saltin, B. (1985) · The American Journal of Cardiology · doi:10.1016/0002-9149(85)91054-9 · Cited by 284
Pulsed Doppler with B-mode imaging for quantitative blood flow measurement
Gill, R. W. (1979) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(79)90014-0 · Cited by 265
Walløe, L., & Wesche, J. (1988) · The Journal of Physiology · doi:10.1113/jphysiol.1988.sp017332 · Cited by 177
The blood flow through the human calf during rhythmic exercise
Barcroft, H., & Dornhorst, A. (1949) · The Journal of Physiology · doi:10.1113/jphysiol.1949.sp004403 · Cited by 144
Faster femoral artery blood velocity kinetics at the onset of exercise following short-term training
Shoemaker, J. K., Phillips, S. M., Green, H. J., & Hughson, R. L. (1996) · Cardiovascular Research · doi:10.1016/s0008-6363(95)00199-9 · Cited by 118
Measurement of volume flow in the human common femoral artery using a duplex ultrasound system
Lewis, P., Psaila, J. V., Davies, W. T., McCarty, K., & Woodcock, J. P. (1986) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(86)90075-x · Cited by 116
Cited by
Medicine & science in sports & exercise
(1994) · Journal of the American Dietetic Association · doi:10.1016/0002-8223(94)92575-5 · Cited by 1,303
Steensberg, A., van Hall, G., Osada, T., Sacchetti, M., Saltin, B., & Pedersen, B. K. (2000) · The Journal of Physiology · doi:10.1111/j.1469-7793.2000.00237.x · Cited by 1,095
Effect of exercise training on endothelium‐derived nitric oxide function in humans
Green, D. J., Maiorana, A., O'Driscoll, G., & Taylor, R. (2004) · The Journal of Physiology · doi:10.1113/jphysiol.2004.068197 · Cited by 1,040
Shear Stress Mediates Endothelial Adaptations to Exercise Training in Humans
Tinken, T. M., Thijssen, D. H. J., Hopkins, N., Dawson, E. A., Cable, N. T., & Green, D. J. (2010) · Hypertension · doi:10.1161/hypertensionaha.109.146282 · Cited by 493
Steensberg, A., Febbraio, M. A., Osada, T., Schjerling, P., van Hall, G., Saltin, B., & Pedersen, B. K. (2001) · The Journal of Physiology · doi:10.1111/j.1469-7793.2001.00633.x · Cited by 443
Metadata
- Authors
- Rådegran, G.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 1997-10-01
- Volume
- 83
- Issue
- 4
- Pages
- 1383-1388
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2164714615
- Cited by
- 297
- References
- 17
- FWCI
- 18.59
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Ultrasound Doppler estimates of femoral artery blood flow during dynamic knee extensor exercise in humans. https://app.cochat.ai/papers/10.1152/jappl.1997.83.4.1383
- The paper
- Rådegran, G. (1997). Ultrasound Doppler estimates of femoral artery blood flow during dynamic knee extensor exercise in humans. Journal of Applied Physiology. https://doi.org/10.1152/jappl.1997.83.4.1383
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.