The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Ultrasound Doppler estimates of femoral artery blood flow during dynamic knee extensor exercise in humans
Abstract
Rådegran, G. Ultrasound Doppler estimates of femoral artery blood flow during dynamic knee extensor exercise in humans. J. Appl. Physiol.83(4): 1383–1388, 1997.—Ultrasound Doppler has been used to measure arterial inflow to a human limb during intermittent static contractions. The technique, however, has neither been thoroughly validated nor used during dynamic exercise. In this study, the inherent problems of the technique have been addressed, and the accuracy was improved by storing the velocity tracings continuously and calculating the flow in relation to the muscle contraction-relaxation phases. The femoral arterial diameter measurements were reproducible with a mean coefficient of variation within the subjects of 1.2 ± 0.2%. The diameter was the same whether the probe was fixed or repositioned at rest (10.8 ± 0.2 mm) or measured during dynamic exercise. The blood velocity was sampled over the width of the diameter and the parabolic velocity profile, since sampling in the center resulted in an overestimation by 22.6 ± 9.1% ( P< 0.02). The femoral arterial Doppler blood flow increased linearly ( r = 0.997, P < 0.001) with increasing load [Doppler blood flow = 0.080 ⋅ load (W) + 1.446 l/min] and was correlated positively with simultaneous thermodilution venous outflow measurements ( r = 0.996, P < 0.001). The two techniques were linearly related (Doppler = thermodilution ⋅ 0.985 + 0.071 l/min; r = 0.996, P < 0.001), with a coefficient of variation of ∼6% for both methods.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Maximal perfusion of skeletal muscle in man.
Andersen, P., & Saltin, B. (1985) · The Journal of Physiology · doi:10.1113/jphysiol.1985.sp015794 · Cited by 1,250
Measurement of blood flow by ultrasound: Accuracy and sources of error
Gill, R. W. (1985) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(85)90035-3 · Cited by 765
Dynamic knee extension as model for study of isolated exercising muscle in humans
Andersen, P., Adams, R. P., Sjogaard, G., Thorboe, A., & Saltin, B. (1985) · Journal of Applied Physiology · doi:10.1152/jappl.1985.59.5.1647 · Cited by 384
Leg Blood Flow during Exercise in Man
Jorfeldt, L., & Wahren, J. (1971) · Clinical Science · doi:10.1042/cs0410459 · Cited by 362
Hemodynamic adaptations to exercise
Saltin, B. (1985) · The American Journal of Cardiology · doi:10.1016/0002-9149(85)91054-9 · Cited by 284
Pulsed Doppler with B-mode imaging for quantitative blood flow measurement
Gill, R. W. (1979) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(79)90014-0 · Cited by 265
Walløe, L., & Wesche, J. (1988) · The Journal of Physiology · doi:10.1113/jphysiol.1988.sp017332 · Cited by 177
The blood flow through the human calf during rhythmic exercise
Barcroft, H., & Dornhorst, A. C. (1949) · The Journal of Physiology · doi:10.1113/jphysiol.1949.sp004403 · Cited by 158
Faster femoral artery blood velocity kinetics at the onset of exercise following short-term training
Shoemaker, J. K., Phillips, S. M., Green, H. J., & Hughson, R. L. (1996) · Cardiovascular Research · doi:10.1016/s0008-6363(95)00199-9 · Cited by 127
Measurement of volume flow in the human common femoral artery using a duplex ultrasound system
Lewis, P., Psaila, J. V., Davies, W. T., McCarty, K., & Woodcock, J. P. (1986) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(86)90075-x · Cited by 116
Cited by
Medicine & science in sports & exercise
(1994) · Journal of the American Dietetic Association · doi:10.1016/0002-8223(94)92575-5 · Cited by 1,303
Steensberg, A., van Hall, G., Osada, T., Sacchetti, M., Saltin, B., & Pedersen, B. K. (2000) · The Journal of Physiology · doi:10.1111/j.1469-7793.2000.00237.x · Cited by 1,095
“At each sample point the femoral arterial blood flow was measured with the ultrasound Doppler technique as previously validated (Radegran, 1997).”
MethodEffect of exercise training on endothelium‐derived nitric oxide function in humans
Green, D. J., Maiorana, A., O'Driscoll, G., & Taylor, R. (2004) · The Journal of Physiology · doi:10.1113/jphysiol.2004.068197 · Cited by 1,040
Shear Stress Mediates Endothelial Adaptations to Exercise Training in Humans
Tinken, T. M., Thijssen, D. H. J., Hopkins, N., Dawson, E. A., Cable, N. T., & Green, D. J. (2010) · Hypertension · doi:10.1161/hypertensionaha.109.146282 · Cited by 493
Steensberg, A., Febbraio, M. A., Osada, T., Schjerling, P., van Hall, G., Saltin, B., & Pedersen, B. K. (2001) · The Journal of Physiology · doi:10.1111/j.1469-7793.2001.00633.x · Cited by 443
IL-6 and TNF-α expression in, and release from, contracting human skeletal muscle
Steensberg, A., Keller, C., Starkie, R. L., Osada, T., Febbraio, M. A., & Pedersen, B. K. (2002) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.00255.2002 · Cited by 410
“with ultrasound Doppler as previously validated (26).”
Fatiguing inspiratory muscle work causes reflex reduction in resting leg blood flow in humans
Sheel, A. W., Derchak, P. A., Morgan, B. J., Pegelow, D. F., Jacques, A. J., & Dempsey, J. A. (2001) · The Journal of Physiology · doi:10.1111/j.1469-7793.2001.0277k.x · Cited by 331
González-Alonso, J., Olsen, D. B., & Saltin, B. (2002) · Circulation Research · doi:10.1161/01.res.0000044939.73286.e2 · Cited by 331
Impact of inactivity and exercise on the vasculature in humans
Thijssen, D. H. J., Maiorana, A. J., O’Driscoll, G., Cable, N. T., Hopman, M. T. E., & Green, D. J. (2010) · European Journal of Applied Physiology · doi:10.1007/s00421-009-1260-x · Cited by 308
Fischer, C. P., Hiscock, N. J., Penkowa, M., Basu, S., Vessby, B., Kallner, A., Sjöberg, L., & Pedersen, B. K. (2004) · The Journal of Physiology · doi:10.1113/jphysiol.2004.066779 · Cited by 293
Muscle blood f low at onset of dynamic exercise in humans
Rådegran, G., & Saltin, B. (1998) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1998.274.1.h314 · Cited by 271
Self-citationPyke, K. E., Dwyer, E. M., & Tschakovsky, M. E. (2004) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01245.2003 · Cited by 258
Pilegaard, H., Osada, T., Andersen, L. T., Helge, J. W., Saltin, B., & Neufer, P. D. (2005) · Metabolism · doi:10.1016/j.metabol.2005.03.008 · Cited by 154
Muscle Oxygenation Trends During Dynamic Exercise Measured by Near Infrared Spectroscopy
Bhambhani, Y. N. (2004) · Canadian Journal of Applied Physiology · doi:10.1139/h04-033 · Cited by 149
“The latter is likely due to the fact that during the transition from rest to maximal exercise, the increase in intramuscular pressure during the contraction phase exceeds the rise in intravascular pressure, thereby decreasing the ability of blood to perfuse the exercising muscle (Radegran, 1997).”
BackgroundSteensberg, A., Fischer, C. P., Sacchetti, M., Keller, C., Osada, T., Schjerling, P., van Hall, G., Febbraio, M. A., & Pedersen, B. K. (2003) · The Journal of Physiology · doi:10.1113/jphysiol.2002.032938 · Cited by 152
Tumor Necrosis Factor-α Modulates Human in Vivo Lipolysis
Plomgaard, P., Fischer, C. P., Ibfelt, T., Pedersen, B. K., & van Hall, G. (2008) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2007-1761 · Cited by 97
Dufour, S. P., Patel, R. P., Brandon, A., Teng, X., Pearson, J., Barker, H., Ali, L., Yuen, A. H. Y., Smolenski, R. T., & González-Alonso, J. (2010) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00389.2010 · Cited by 45
“Anterograde, retrograde and net leg blood flow (LBF) were measured for ~1 min by ultrasound Doppler (Vivid 7, GE Medical Systems, Bedford, UK) (46) after 8 min of rest and after 4 min of exercise.”
MethodAguiar, A. F., Balvedi, M. C. W., Buzzachera, C. F., Altimari, L. R., Lozovoy, M. A. B., Bigliassi, M., Januário, R. S. B., Pereira, R. M., Sanches, V. C., da Silva, D. K., et al. (2016) · European Journal of Nutrition · doi:10.1007/s00394-015-1019-6 · Cited by 21
Effect of histamine-receptor antagonism on leg blood flow during exercise
Ely, M. R., Ratchford, S. M., La Salle, D. T., Trinity, J. D., Wray, D. W., & Halliwill, J. R. (2020) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00689.2019 · Cited by 14
Reinpõld, K., Rannama, I., & Port, K. (2024) · Sports · doi:10.3390/sports12020040 · Cited by 8
Metadata
- Authors
- Rådegran, G.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 1997-10-01
- Volume
- 83
- Issue
- 4
- Pages
- 1383-1388
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2164714615
- Cited by
- 297
- References
- 17
- FWCI
- 18.59
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.