Control of breathing during sleep assessed by proportional assist ventilation
Open accessThe DOI matches its Crossref record.
Abstract
Meza, S., E. Giannouli, and M. Younes. Control of breathing during sleep assessed by proportional assist ventilation. J. Appl. Physiol. 84(1): 3–12, 1998.—We used proportional assist ventilation (PAV) to evaluate the sources of respiratory drive during sleep. PAV increases the slope of the relation between tidal volume (Vt) and respiratory muscle pressure output (Pmus). We reasoned that if respiratory drive is dominated by chemical factors, progressive increase of PAV gain should result in only a small increase in Vt because Pmus would be downregulated substantially as a result of small decreases in[Formula: see text]. In the presence of substantial nonchemical sources of drive [believed to be the case in rapid-eye-movement (REM) sleep] PAV should result in a substantial increase in minute ventilation and reduction in [Formula: see text] as the output related to the chemically insensitive drive source is amplified severalfold. Twelve normal subjects underwent polysomnography while connected to a PAV ventilator. Continuous positive air pressure (5.2 ± 2.0 cmH 2 O) was administered to stabilize the upper airway. PAV was increased in 2-min steps from 0 to 20, 40, 60, 80, and 90% of the subject’s elastance and resistance. Vt, respiratory rate, minute ventilation, and end-tidal CO 2 pressure were measured at the different levels, and Pmus was calculated. Observations were obtained in stage 2 sleep ( n = 12), slow-wave sleep ( n = 11), and REM sleep ( n = 7). In all cases, Pmus was substantially downregulated with increase in assist so that the increase in Vt, although significant ( P < 0.05), was small (0.08 liter at the highest assist). There was no difference in response between REM and non-REM sleep. We conclude that respiratory drive during sleep is dominated by chemical control and that there is no fundamental difference between REM and non-REM sleep in this regard. REM sleep appears to simply add bidirectional noise to what is basically a chemically controlled respiratory output.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Malhotra, A., & White, D. P. (2002) · The Lancet · doi:10.1016/s0140-6736(02)09464-3 · Cited by 1,190
Chemical Control Stability in Patients with Obstructive Sleep Apnea
YOUNES, M., OSTROWSKI, M., THOMPSON, W., LESLIE, C., & SHEWCHUK, W. (2001) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.163.5.2007013 · Cited by 439
Self-citationSleep {middle dot} 2: Pathophysiology of obstructive sleep apnoea/hypopnoea syndrome
Fogel, R. B. (2004) · Thorax · doi:10.1136/thorax.2003.015859 · Cited by 291
Quantifying the ventilatory control contribution to sleep apnoea using polysomnography
Terrill, P. I., Edwards, B. A., Nemati, S., Butler, J. P., Owens, R. L., Eckert, D. J., White, D. P., Malhotra, A., Wellman, A., & Sands, S. A. (2015) · European Respiratory Journal · doi:10.1183/09031936.00062914 · Cited by 289
“Available methods require patient intervention [3, 17, 37], additional measurements ( e.g. end-tidal gases or intrathoracic pressure) [25, 26] and all disrupt the pattern of OSA under investigation ( e.g. requiring CPAP or wakefulness).”
Crossing the apnoeic threshold: causes and consequences
Dempsey, J. A. (2005) · Experimental Physiology · doi:10.1113/expphysiol.2004.028985 · Cited by 280
Stable breathing through deeper sleeping
Saboisky, J., Eckert, D., & Malhotra, A. (2010) · Thorax · doi:10.1136/thx.2009.127860 · Cited by 19
Metadata
- Authors
- Meza, S., Giannouli, E., & Younes, M.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 1998-01-01
- Volume
- 84
- Issue
- 1
- Pages
- 3-12
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2258738341
- Cited by
- 70
- References
- 0
- FWCI
- 1.53
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.