Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 165

The DOI matches its Crossref record.

Effects of lung volume on diaphragm EMG signal strength during voluntary contractions

Beck, Jennifer, Sinderby, Christer, Lindström, Lars, Grassino, Alex·1998·Journal of Applied Physiology

Abstract

The use of esophageal recordings of the diaphragm electromyogram (EMG) signal strength to evaluate diaphragm activation during voluntary contractions in humans has recently been criticized because of a possible artifact created by changes in lung volume. Therefore, the first aim of this study was to evaluate whether there is an artifactual influence of lung volume on the strength of the diaphragm EMG during voluntary contractions. The second aim was to measure the required changes in activation for changes in lung volume at a given tension, i.e., the volume-activation relationship of the diaphragm. Healthy subjects ( n = 6) performed contractions of the diaphragm at different transdiaphragmatic pressure (Pdi) targets (range 20–160 cmH 2 O) while maintaining chest wall configuration constant at different lung volumes. The diaphragm EMG was recorded with a multiple-array esophageal electrode, with control of signal contamination and electrode positioning. The effects of lung volume on the EMG were studied by comparing the crural diaphragm EMG root mean square (RMS), an index of crural diaphragm activation, with an index of global diaphragm activation obtained by normalizing Pdi to the maximum Pdi at the given muscle length (Pdi/P[Formula: see text]) at the different lung volumes. We observed a direct relationship between RMS and Pdi/P[Formula: see text]independent of diaphragm length. The volume-activation relationship of the diaphragm was equally affected by changes in lung volume as the volume-Pdi relationship (60% change from functional residual capacity to total lung capacity). We conclude that the RMS of the diaphragm EMG is not artifactually influenced by lung volume and can be used as a reliable index of diaphragm activation. The volume-activation relationship can be used to infer changes in the length-tension relationship of the diaphragm at submaximal activation/contraction levels.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1152/jappl.1998.85.3.1123

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 165

Metadata

Authors
Beck, J., Sinderby, C., Lindström, L., & Grassino, A.
Venue
Journal of Applied Physiology
Published
1998-09-01
Volume
85
Issue
3
Pages
1123-1134
ISSN
  • 0161-7567 (ISSN-L)
  • 8750-7587
  • 1522-1601
OpenAlex
W1927839424
Cited by
165
References
0
FWCI
3.98
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Effects of lung volume on diaphragm EMG signal strength during voluntary contractions. https://app.cochat.ai/papers/10.1152/jappl.1998.85.3.1123
The paper
Beck, J., Sinderby, C., Lindström, L., & Grassino, A. (1998). Effects of lung volume on diaphragm EMG signal strength during voluntary contractions. Journal of Applied Physiology. https://doi.org/10.1152/jappl.1998.85.3.1123

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.