Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 253

The DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.

Faster adjustment of O2delivery does not affect V˙o 2 on-kinetics in isolated in situ canine muscle

Grassi, Bruno, Gladden, L. Bruce, Samaja, Michele, Stary, Creed M., Hogan, Michael C. · 1998 · Journal of Applied Physiology

Abstract

The mechanism(s) limiting muscle O 2 uptake (V˙o 2) kinetics was investigated in isolated canine gastrocnemius muscles ( n = 7) during transitions from rest to 3 min of electrically stimulated isometric tetanic contractions (200-ms trains, 50 Hz; 1 contraction/2 s; 60–70% of peakV˙o 2). Two conditions were mainly compared: 1) spontaneous adjustment of blood flow (Q˙) [control, spontaneousQ˙ (C Spont)]; and 2) pump-perfusedQ˙, adjusted ∼15 s before contractions at a constant level corresponding to the steady-state value during contractions in C Spont [faster adjustment of O 2 delivery (Fast O 2 Delivery)]. During Fast O 2 Delivery, 1–2 ml/min of 10−2 M adenosine were infused intra-arterially to prevent inordinate pressure increases with the elevated Q˙. The purpose of the study was to determine whether a faster adjustment of O 2 delivery would affectV˙o 2 kinetics.Q˙ was measured continuously; arterial ([Formula: see text]) and popliteal venous ([Formula: see text]) O 2 contents were determined at rest and at 5- to 7-s intervals during contractions; O 2 delivery was calculated asQ˙ ⋅ [Formula: see text], and V˙o 2 was calculated asQ˙ ⋅ arteriovenous O 2 content difference. Times to reach 63% of the difference between baseline and steady-stateV˙o 2 during contractions were 23.8 ± 2.0 (SE) s in C Spont and 21.8 ± 0.9 s in Fast O 2 Delivery (not significant). In the present experimental model, elimination of any delay in O 2 delivery during the rest-to-contraction transition did not affect muscleV˙o 2 kinetics, which suggests that this kinetics was mainly set by an intrinsic inertia of oxidative metabolism.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1152/jappl.1998.85.4.1394

Cites

33 of 33 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 33 references

Cited by

See all 253

Metadata

Authors
Grassi, B., Gladden, L. B., Samaja, M., Stary, C. M., & Hogan, M. C.
Venue
Journal of Applied Physiology
Published
1998-10-01
Volume
85
Issue
4
Pages
1394-1403
ISSN
  • 0161-7567 (ISSN-L)
  • 8750-7587
  • 1522-1601
OpenAlex
W2176163875
Cited by
253
References
33
FWCI
17.11
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Faster adjustment of O2delivery does not affect V˙o 2 on-kinetics in isolated in situ canine muscle. https://app.cochat.ai/papers/10.1152/jappl.1998.85.4.1394
The paper
Grassi, B., Gladden, L. B., Samaja, M., Stary, C. M., & Hogan, M. C. (1998). Faster adjustment of O2delivery does not affect V˙o 2 on-kinetics in isolated in situ canine muscle. Journal of Applied Physiology. https://doi.org/10.1152/jappl.1998.85.4.1394

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.