Peripheral O2 diffusion does not affect V˙o 2 on-kinetics in isolated in situ canine muscle
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
To test the hypothesis that muscle O 2 uptake (V˙o 2) on-kinetics is limited, at least in part, by peripheral O 2 diffusion, we determined theV˙o 2 on-kinetics in 1) normoxia (Control); 2) hyperoxic gas breathing (Hyperoxia); and 3) hyperoxia and the administration of a drug (RSR-13, Allos Therapeutics), which right-shifts the Hb-O 2 dissociation curve (Hyperoxia+RSR-13). The study was conducted in isolated canine gastrocnemius muscles ( n = 5) during transitions from rest to 3 min of electrically stimulated isometric tetanic contractions (200-ms trains, 50 Hz; 1 contraction/2 s; 60–70% peakV˙o 2). In all conditions, before and during contractions, muscle was pump perfused with constantly elevated blood flow (Q˙), at a level measured at steady state during contractions in preliminary trials with spontaneous Q˙. Adenosine was infused intra-arterially to prevent inordinate pressure increases with the elevated Q˙. Q˙ was measured continuously, arterial and popliteal venous O 2 concentrations were determined at rest and at 5- to 7-s intervals during contractions, andV˙o 2 was calculated asQ˙ ⋅ arteriovenous O 2 content difference.[Formula: see text] at 50% Hbo 2 saturation (P 50) was calculated. Mean capillary [Formula: see text](P [Formula: see text]) was estimated by numerical integration. P 50 was higher in Hyperoxia+RSR-13 [40 ± 1 (SE) Torr] than in Control and in Hyperoxia (31 ± 1 Torr). After 15 s of contractions,P [Formula: see text]was higher in Hyperoxia (97 ± 9 Torr) vs. Control (53 ± 3 Torr) and in Hyperoxia+RSR-13 (197 ± 39 Torr) vs. Hyperoxia. The time to reach 63% of the difference between baseline and steady-stateV˙o 2 during contractions was 24.7 ± 2.7 s in Control, 26.3 ± 0.8 s in Hyperoxia, and 24.7 ± 1.1 s in Hyperoxia+RSR-13 (not significant). Enhancement of peripheral O 2 diffusion (obtained by increasedP [Formula: see text]at constant O 2 delivery) during the rest-to-contraction (60–70% of peakV˙o 2) transition did not affect muscle V˙o 2 on-kinetics.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Myoglobin O2 desaturation during exercise. Evidence of limited O2 transport.
Richardson, R. S., Noyszewski, E. A., Kendrick, K. F., Leigh, J. S., & Wagner, P. D. (1995) · Journal of Clinical Investigation · doi:10.1172/jci118237 · Cited by 647
Self-citationMuscle O2 uptake kinetics in humans: implications for metabolic control
Grassi, B., Poole, D. C., Richardson, R. S., Knight, D. R., Erickson, B. K., & Wagner, P. D. (1996) · Journal of Applied Physiology · doi:10.1152/jappl.1996.80.3.988 · Cited by 561
Self-citationMahler, M. (1985) · The Journal of general physiology · doi:10.1085/jgp.86.1.135 · Cited by 234
Cited by
Fiber Types in Mammalian Skeletal Muscles
Schiaffino, S., & Reggiani, C. (2011) · Physiological Reviews · doi:10.1152/physrev.00031.2010 · Cited by 3,022
“First, a lag in muscle blood flow may limit oxygen delivery at the onset of exercise, although recent studies (286, 287) have reduced the weight of this factor.”
BackgroundBishop, D. (2003) · Sports Medicine · doi:10.2165/00007256-200333060-00005 · Cited by 715
Poole, D. C., & Jones, A. M. (2012) · Comprehensive Physiology · doi:10.1002/cphy.c100072 · Cited by 514
Grassi, B., Pogliaghi, S., Rampichini, S., Quaresima, V., Ferrari, M., Marconi, C., & Cerretelli, P. (2003) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00695.2002 · Cited by 429
Self-citationStephens, F. B., Constantin‐Teodosiu, D., & Greenhaff, P. L. (2007) · The Journal of Physiology · doi:10.1113/jphysiol.2006.125799 · Cited by 396
“…by a rapid hydrolysis of phosphocreatine (PCr) and accumulation of lactate), which is attributable to inertia in mitochondrial ATP production (Yoshida et al. 1995; Grassi et al. 1998a, 1998b), rather than the classically accepted theory of a delay in muscle oxygen delivery (Margaria et al. 1965).”
BackgroundSlow Component of V˙O2 Kinetics: Mechanistic Bases and Practical Applications
JONES, A. M., GRASSI, B., CHRISTENSEN, P. M., KRUSTRUP, P., BANGSBO, J., & POOLE, D. C. (2011) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31821fcfc1 · Cited by 353
Self-citationEffects of prior heavy exercise on phase II pulmonary oxygen uptake kinetics during heavy exercise
Burnley, M., Jones, A. M., Carter, H., & Doust, J. H. (2000) · Journal of Applied Physiology · doi:10.1152/jappl.2000.89.4.1387 · Cited by 255
Interaction of factors determining oxygen uptake at the onset of exercise
Tschakovsky, M. E., & Hughson, R. L. (1999) · Journal of Applied Physiology · doi:10.1152/jappl.1999.86.4.1101 · Cited by 254
Muscle oxygen kinetics at onset of intense dynamic exercise in humans
Bangsbo, J., Krustrup, P., González-Alonso, J., Boushel, R., & Saltin, B. (2000) · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · doi:10.1152/ajpregu.2000.279.3.r899 · Cited by 220
Pringle, J. S. M., Doust, J. H., Carter, H., Tolfrey, K., Campbell, I. T., & Jones, A. M. (2003) · European Journal of Applied Physiology · doi:10.1007/s00421-003-0799-1 · Cited by 216
“…and colleagues demonstrated that neither improving convective O2 delivery by pump-perfusing muscle to levels associated with steady-state exercise (Grassi et al. 1998a), nor enhancing peripheral O2 diffusion by infusing RSR-13 in the same model (Grassi et al. 1998b), influenced _V O2 on-kinetics…”
Dynamics of microvascular oxygen pressure across the rest-exercise transition in rat skeletal muscle
Behnke, B. J., Kindig, C. A., Musch, T. I., Koga, S., & Poole, D. C. (2001) · Respiration Physiology · doi:10.1016/s0034-5687(01)00195-5 · Cited by 187
The role of oxygen in determining phosphocreatine onset kinetics in exercising humans
Haseler, L. J., Kindig, C. A., Richardson, R. S., & Hogan, M. C. (2004) · The Journal of Physiology · doi:10.1113/jphysiol.2004.062042 · Cited by 78
“…the isolated dog hindlimb preparation, acute manipulations in Q̇O2 and/or availability of O2 did not affect V̇O2 on-kinetics during moderate intensity exercise (Grassi et al. 1998a,b), but increasing O2 delivery did speed V̇O2 kinetics in response to maximal intensity exercise (Grassi et al. 2000).”
BackgroundSelf-citationKindig, C. A., McDonough, P., Erickson, H. H., & Poole, D. C. (2002) · Respiratory Physiology & Neurobiology · doi:10.1016/s1569-9048(02)00068-x · Cited by 62
Metadata
- Authors
- Grassi, B., Gladden, L. B., Stary, C. M., Wagner, P. D., & Hogan, M. C.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 1998-10-01
- Volume
- 85
- Issue
- 4
- Pages
- 1404-1412
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2270484223
- Cited by
- 157
- References
- 3
- FWCI
- 12.12
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.