CoChat

Magnitude and time course of hemodynamic responses to Mueller maneuvers in patients with congestive heart failure

Hall, Michael J., Ando, Shin-Ichi, Floras, John S., Bradley, T. Douglas · 1998 · Journal of Applied Physiology
Cited by 86

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

To simulate the immediate hemodynamic effect of negative intrathoracic pressure during obstructive apneas in congestive heart failure (CHF), without inducing confounding factors such as hypoxia and arousals from sleep, eight awake patients performed, at random, 15-s Mueller maneuvers (MM) at target intrathoracic pressures of −20 (MM −20) and −40 cmH 2 O (MM −40), confirmed by esophageal pressure, and 15-s breath holds, as apneic time controls. Compared with quiet breathing, at baseline, before these interventions, the immediate effects [first 5 cardiac cycles (SD), P values refer to MM −40 compared with breath holds] of apnea, MM −20, and MM −40 were, for left ventricular (LV) systolic transmural pressure (Ptm), 1.0 ± 1.9, 7.2 ± 3.5, and 11.3 ± 6.8 mmHg ( P < 0.01); for systolic blood pressure (SBP), 2.9 ± 2.6, −5.5 ± 3.4, and −12.1 ± 6.8 mmHg ( P < 0.01); and for stroke volume (SV) index, 0.4 ± 2.8, −4.1 ± 2.8, and −6.9 ± 2.3 ml/m 2( P < 0.001), respectively. Corresponding values over the last five cardiac cycles were for LVPtm 6.4 ± 4.4, 5.4 ± 6.6, and −4.5 ± 9.1 mmHg ( P < 0.01); for SBP 6.9 ± 4.2, −8.2 ± 7.7, and −24.2 ± 6.9 mmHg ( P < 0.01); and for SV index −0.4 ± 2.1, −5.2 ± 2.8, and −9.2 ± 4.8 ml/m 2( P < 0.001), respectively. Thus, in CHF patients, the initial hemodynamic response to the generation of negative intrathoracic pressure includes an immediate increase in LV afterload and an abrupt fall in SV. The magnitude of response is proportional to the intensity of the MM stimulus. By the end of a 15-s MM −40, LVPtm falls below baseline values, yet SV and SBP do not recover. Thus, when −40 cmH 2 O intrathoracic pressure is sustained, additional mechanisms, such as a drop in LV preload due to ventricular interaction, are engaged, further reducing SV. The net effect of MM −40 was a 33% reduction in SV index (from 27 to 18 ml/min 2), and a 21% reduction in SBP (from 121 to 96 mmHg). Obstructive apneas can have adverse effects on systemic and, possibly, coronary perfusion in CHF through dynamic mechanisms that are both stimulus and time dependent.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1152/jappl.1998.85.4.1476

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 86

Metadata

Authors
Hall, M. J., Ando, S.-I., Floras, J. S., & Bradley, T. D.
Venue
Journal of Applied Physiology
Published
1998-10-01
Volume
85
Issue
4
Pages
1476-1484
ISSN
  • 0161-7567 (ISSN-L)
  • 8750-7587
  • 1522-1601
OpenAlex
W2107444371
Cited by
86
References
3
FWCI
1.61
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Magnitude and time course of hemodynamic responses to Mueller maneuvers in patients with congestive heart failure. https://app.cochat.ai/papers/10.1152/jappl.1998.85.4.1476
The paper
Hall, M. J., Ando, S.-I., Floras, J. S., & Bradley, T. D. (1998). Magnitude and time course of hemodynamic responses to Mueller maneuvers in patients with congestive heart failure. Journal of Applied Physiology. https://doi.org/10.1152/jappl.1998.85.4.1476

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.