CoChat

Regional deposition and retention of particles in shallow, inhaled boluses: effect of lung volume

Bennett, William D., Scheuch, Gerhard, Zeman, Kirby L., Brown, James S., Kim, Chong, Heyder, Joachim, Stahlhofen, Willi · 1999 · Journal of Applied Physiology
Cited by 36

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

The regional deposition of particles in boluses delivered to shallow lung depths and their subsequent retention in the airways may depend on the lung volume at which the boluses are delivered. To evaluate the effect of end-inspiratory lung volume on aerosol bolus delivery, we had healthy subjects inhale radiolabeled, monodisperse aerosol (99m Tc-iron oxide, 3.5-μm mass median aerodynamic diameter) boluses (40 ml) to a volumetric front depth of 70 ml into the lung at lung volumes of 50, 70, and 85% of total lung capacity (TLC) end inhalation. By gamma camera analysis, we found significantly greater deposition in the left (L) vs. right (R) lungs at the 70 and 85% TLC end inhalation; ratio of deposition in L to R lung, normalized to L-to-R ratio of lung volume (mean L/R), was 1.60 ± 0.45 (SD) and 1.96 ± 0.72, respectively ( P < 0.001 for comparison to 1.0) for posterior images. However, at 50% TLC, L/R was 1.23 ± 0.37, not significantly different from 1.0. These data suggest that the L and R lungs may be expanding nonuniformly at higher lung volumes. On the other hand, subsequent retention of deposited particles at 2 and 24 h postdeposition was independent of L/R at the various lung volumes. Thus asymmetric bolus ventilation for these very shallow boluses does not lead to significant increases in peripheral alveolar deposition. These data may prove useful for 1) designing aerosol delivery techniques to target bronchial airways and 2) understanding airway retention of inhaled particles.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1152/jappl.1999.86.1.168

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 36

Metadata

Authors
Bennett, W. D., Scheuch, G., Zeman, K. L., Brown, J. S., Kim, C., Heyder, J., & Stahlhofen, W.
Venue
Journal of Applied Physiology
Published
1999-01-01
Volume
86
Issue
1
Pages
168-173
ISSN
  • 0161-7567 (ISSN-L)
  • 8750-7587
  • 1522-1601
OpenAlex
W2150000487
Cited by
36
References
1
FWCI
1.19
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Regional deposition and retention of particles in shallow, inhaled boluses: effect of lung volume. https://app.cochat.ai/papers/10.1152/jappl.1999.86.1.168
The paper
Bennett, W. D., Scheuch, G., Zeman, K. L., Brown, J. S., Kim, C., Heyder, J., & Stahlhofen, W. (1999). Regional deposition and retention of particles in shallow, inhaled boluses: effect of lung volume. Journal of Applied Physiology. https://doi.org/10.1152/jappl.1999.86.1.168

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.