The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Oximetry of retinal vessels by dual-wavelength imaging: calibration and influence of pigmentation
Abstract
A method for noninvasive measurement of Hb O 2 saturation (So 2) in retinal blood vessels by digital imaging was developed and tested. Images of vessels were recorded at O 2-sensitive and O 2-insensitive wavelengths (600 and 569 nm, respectively) by using a modified fundus camera with an image splitter coupled to an 18-bit digital camera. Retinal arterial So 2 was varied experimentally by having subjects breathe mixtures of O 2 and N 2 while systemic arterial So 2 was monitored with a pulse oximeter. Optical densities (ODs) of vascular segments were determined using a computer algorithm to track the path of reflected light intensity along vessels. During graded hypoxia the OD ratio (ODR = OD 600/OD 569) bore an inverse linear relationship to systemic So 2. Compensation for the influence of choroidal pigmentation significantly reduced variation in the arterial So 2 measurements among subjects. An O 2 sensitivity of 0.00504 ± 0.00029 (SE) ODR units/%So 2 was determined. Retinal venous So 2 at normoxia was 55 ± 3.38% (SE). Breathing 100% O 2 increased venous So 2 by 19.2 ± 2.9%. This technique, when combined with blood flow studies in human subjects, will enable the study of retinal O 2 utilization under experimental and various disease conditions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Spectral reflectance of the human ocular fundus
Delori, F. C., & Pflibsen, K. P. (1989) · Applied Optics · doi:10.1364/ao.28.001061 · Cited by 377
Spectrophotometry of Haemoglobin Derivatives.
(1971) · Annals of Internal Medicine · doi:10.7326/0003-4819-75-1-150 · Cited by 263
Noninvasive technique for oximetry of blood in retinal vessels
Delori, F. C. (1988) · Applied Optics · doi:10.1364/ao.27.001113 · Cited by 207
HICKAM, J. B., & FRAYSER, R. (1966) · Circulation · doi:10.1161/01.cir.33.2.302 · Cited by 191
Noninvasive Detection of Profound Arterial Desaturations Using a Pulse Oximetry Device
Mihm, F. G., & Halperin, B. D. (1985) · Anesthesiology · doi:10.1097/00000542-198501000-00020 · Cited by 142
Retinal oxygen consumption during hyperglycemia in patients with diabetes without retinopathy
Tiedeman, J. S., Kirk, S. E., Srinivas, S., et al. (1998) · Ophthalmology · doi:10.1016/s0161-6420(98)71029-1 · Cited by 109
Self-citationEvaluation of the Ohmeda 3700 Pulse Oximeter: Steady-state and Transient Response Characteristics
Kagle, D. M., Alexander, C. M., Berko, R. S., Gluffre, M., & Gross, J. B. (1987) · Anesthesiology · doi:10.1097/00000542-198703000-00018 · Cited by 108
A clinical evaluation of the accuracy of the Nellcor N-100 and Ohmeda 3700 pulse oximeters
Cecil, W. T., Thorpe, K. J., Fibuch, E. E., & Tuohy, G. F. (1988) · Journal of Clinical Monitoring · doi:10.1007/bf01618105 · Cited by 51
Reflectance pulse oximetry measurements from the retinal fundus
de Kock, J. P., Tarassenko, L., Glynn, C. J., & Hill, A. R. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.238467 · Cited by 36
Cited by
Retinal angiogenesis in development and disease
Gariano, R. F., & Gardner, T. W. (2005) · Nature · doi:10.1038/nature04482 · Cited by 705
Hardarson, S. H., Harris, A., Karlsson, R. A., Halldorsson, G. H., Kagemann, L., Rechtman, E., Zoega, G. M., Eysteinsson, T., Benediktsson, J. A., Thorsteinsson, A., et al. (2006) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.06-0039 · Cited by 276
Self-citation
Metadata
- Authors
- Beach, J. M., Schwenzer, K. J., Srinivas, S., Kim, D., & Tiedeman, J. S.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 1999-02-01
- Volume
- 86
- Issue
- 2
- Pages
- 748-758
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2165196362
- Cited by
- 263
- References
- 9
- FWCI
- 2.13
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Oximetry of retinal vessels by dual-wavelength imaging: calibration and influence of pigmentation. https://app.cochat.ai/papers/10.1152/jappl.1999.86.2.748
- The paper
- Beach, J. M., Schwenzer, K. J., Srinivas, S., Kim, D., & Tiedeman, J. S. (1999). Oximetry of retinal vessels by dual-wavelength imaging: calibration and influence of pigmentation. Journal of Applied Physiology. https://doi.org/10.1152/jappl.1999.86.2.748
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.