Effect of pressure on hydraulic conductivity of endothelial monolayers: role of endothelial cleft shear stress
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Significant changes in transvascular pressure occur in pulmonary hypertension, microgravity, and many other physiological and pathophysiological circumstances. Using bovine aortic endothelial cells grown on porous, rigid supports, we demonstrate that step changes in transmural pressure of 10, 20, and 30 cmH 2 O induce significant elevations in endothelial hydraulic conductivity ( L p) that require 5 h to reach new steady-state levels. The increases in L p can be reversed by addition of a stable cAMP analog (dibutyryl cAMP), and the increases in L p in response to pressure can be inhibited significantly with nitric oxide synthase inhibitors ( N G-monomethyl-l-arginine and nitro-l-arginine methyl ester). The increase in L p was not due to pressure-induced stretch because the endothelial cell (EC) support was rigid. It is unlikely that the increase in L p was due to a direct effect of pressure because exposure of the cells to elevated pressure (25 cmH 2 O) for 4 h had no effect on the volume flux driven by a transmural pressure of 10 cmH 2 O. We hypothesize that elevated endothelial cleft shear stress induced by elevated transmural flow in response to elevated pressure stimulates the increase in L p through a nitric oxide-cAMP-dependent mechanism. This is consistent with recent studies of the effects of shear stress on the luminal surface of ECs. We provide simple estimates of endothelial cleft shear stress, which suggest magnitudes comparable to those imposed by blood flow on the luminal surface of ECs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Flow-mediated endothelial mechanotransduction
Davies, P. F. (1995) · Physiological Reviews · doi:10.1152/physrev.1995.75.3.519 · Cited by 2,802
Cited by
Fluid forces control endothelial sprouting
Song, J. W., & Munn, L. L. (2011) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1105316108 · Cited by 498
“The mechanism of the mechanotransduction is not clear, but previous studies have suggested that transverse flow can act on mechanosensors located at cell–cell junctions of endothelial monolayers (46).”
BackgroundFluid shear stress threshold regulates angiogenic sprouting
Galie, P. A., Nguyen, D.-H. T., Choi, C. K., Cohen, D. M., Janmey, P. A., & Chen, C. S. (2014) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1310842111 · Cited by 421
Shear stress and the endothelial transport barrier
Tarbell, J. M. (2010) · Cardiovascular Research · doi:10.1093/cvr/cvq146 · Cited by 365
Self-citationMass Transport in Arteries and the Localization of Atherosclerosis
Tarbell, J. M. (2003) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.5.040202.121529 · Cited by 281
Self-citationSajkov, D., Wang, T., Saunders, N. A., Bune, A. J., & Douglas Mcevoy, R. (2002) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.165.2.2010092 · Cited by 266
Metadata
- Authors
- Tarbell, J. M., Demaio, L., & Zaw, M. M.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 1999-07-01
- Volume
- 87
- Issue
- 1
- Pages
- 261-268
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2157128304
- Cited by
- 60
- References
- 1
- FWCI
- 1.26
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.