Measurement of limb venous compliance in humans: technical considerations and physiological findings
The DOI matches its Crossref record.
Abstract
We conducted a series of studies to develop and test a rapid, noninvasive method to measure limb venous compliance in humans. First, we measured forearm volume (mercury-in-Silastic strain gauges) and antecubital intravenous pressure during inflation of a venous collecting cuff around the upper arm. Intravenous pressure fit the regression line, −0.3 ± 0.7 + 0.95 ± 0.02 ⋅ cuff pressure ( r = 0.99 ± 0.00), indicating cuff pressure is a good index of intravenous pressure. In subsequent studies, we measured forearm and calf venous compliance by inflating the venous collecting cuff to 60 mmHg for 4 min, then decreasing cuff pressure at 1 mmHg/s (over 1 min) to 0 mmHg, using cuff pressure as an estimate of venous pressure. This method produced pressure-volume curves fitting the quadratic regression (Δlimb volume) = β 0 + β 1 ⋅ (cuff pressure) + β 2 ⋅ (cuff pressure)2, where Δ is change. Curves generated with this method were reproducible from day to day (coefficient of variation: 4.9%). In 11 subjects we measured venous compliance via this method under two conditions: with and without (in random order) superimposed sympathetic activation (ischemic handgrip exercise to fatigue followed by postexercise ischemia). Calf and forearm compliance did not differ between control and sympathetic activation ( P > 0.05); however, the data suggest that unstressed volume was reduced by the maneuver. These studies demonstrate that venous pressure-volume curves can be generated both rapidly and noninvasively with this technique. Furthermore, the results suggest that although whole-limb venous compliance is under negligible sympathetic control in humans, unstressed volume can be affected by the sympathetic nervous system.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Pathophysiological basis of orthostatic hypotension in autonomic failure
Smit, A. A. J., Halliwill, J. R., Low, P. A., & Wieling, W. (1999) · The Journal of Physiology · doi:10.1111/j.1469-7793.1999.0001o.x · Cited by 387
Self-citationAssessment of cardiovascular autonomic function
Freeman, R. (2006) · Clinical Neurophysiology · doi:10.1016/j.clinph.2005.09.027 · Cited by 262
Autonomic control of the venous system in health and disease: effects of drugs
Pang, C. C. Y. (2001) · Pharmacology & Therapeutics · doi:10.1016/s0163-7258(01)00138-3 · Cited by 221
Stewart, J. M. (2002) · Circulation · doi:10.1161/01.cir.0000016348.55378.c4 · Cited by 138
Limb venous compliance in patients with idiopathic orthostatic intolerance and postural tachycardia
Freeman, R., Lirofonis, V., Farquhar, W. B., & Risk, M. (2002) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00817.2001 · Cited by 61
“(8) suggested that cuff pressure is an acceptable surrogate measure of venous pressure between 10 and 60 mmHg.”
BackgroundMethodResultInfluentialStewart, J. M., & Weldon, A. (2000) · Journal of Applied Physiology · doi:10.1152/jappl.2000.89.4.1505 · Cited by 53
“(15), who developed methods to rapidly measure limb venous compliance in humans.”
Background
Metadata
- Authors
- Halliwill, J. R., Minson, C. T., & Joyner, M. J.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 1999-10-01
- Volume
- 87
- Issue
- 4
- Pages
- 1555-1563
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2396687283
- Cited by
- 132
- References
- 0
- FWCI
- 2.49
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.