The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Trace gases in breath of healthy volunteers when fasting and after a protein-calorie meal: a preliminary study
Abstract
The selected ion flow tube technique was used to quantify in breath the trace gases acetone, ammonia, ethanol, isoprene, and methanol during single exhalations while fasting and in response to feeding. Six normal volunteers were fasted for 12 h, and, after baseline breath samples were obtained, were fed a liquid protein-calorie meal to provide 0.47 g/kg of protein (Fortisip). Further breath samples were obtained at 20, 40, and 60 min, and then hourly for a further 5 h. Breath acetone concentrations fell from a maximum during fasting, reaching their nadir between 4 and 5 h. Breath ammonia concentrations fell immediately to one-half their fasting levels before a steady increase to two or three times baseline values at 5 h. There was a brief increase in breath ethanol concentrations after feeding, reflecting detectable ethanol contamination of the food. Subsequently, breath ethanol levels remained low throughout the experimental protocol. Isoprene concentrations did not change significantly, whereas changes in methanol concentrations reflected those in the ambient air. This preliminary study indicates that the selected ion flow tube technique may be used to detect changes in the trace gases present in breath and define their concentrations in the fasting and replete state. Of particular interest is the biphasic response of the breath ammonia concentration after feeding.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Quantitative analysis of ammonia on the breath of patients in end-stage renal failure
Davies, S., Spanel, P., & Smith, D. (1997) · Kidney International · doi:10.1038/ki.1997.324 · Cited by 406
Self-citation
Cited by
Diagnostic potential of breath analysis—focus on volatile organic compounds
Miekisch, W., Schubert, J. K., & Noeldge-Schomburg, G. F. E. (2004) · Clinica Chimica Acta · doi:10.1016/j.cccn.2004.04.023 · Cited by 1,096
Selected ion flow tube mass spectrometry (SIFT‐MS) for on‐line trace gas analysis
Smith, D., & Španěl, P. (2005) · Mass Spectrometry Reviews · doi:10.1002/mas.20033 · Cited by 801
Self-citationMicrobial Volatile Organic Compounds
Korpi, A., Järnberg, J., & Pasanen, A.-L. (2009) · Critical Reviews in Toxicology · doi:10.1080/10408440802291497 · Cited by 596
Breath Sensors for Health Monitoring
Güntner, A. T., Abegg, S., Königstein, K., Gerber, P. A., Schmidt-Trucksäss, A., & Pratsinis, S. E. (2019) · ACS Sensors · doi:10.1021/acssensors.8b00937 · Cited by 410
Advances in Electronic-Nose Technologies Developed for Biomedical Applications
Wilson, A. D., & Baietto, M. (2011) · Sensors · doi:10.3390/s110101105 · Cited by 400
Metadata
- Authors
- Smith, D., Spanel, P., & Davies, S.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 1999-11-01
- Volume
- 87
- Issue
- 5
- Pages
- 1584-1588
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W1947337994
- Cited by
- 180
- References
- 1
- FWCI
- 3.50
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Trace gases in breath of healthy volunteers when fasting and after a protein-calorie meal: a preliminary study. https://app.cochat.ai/papers/10.1152/jappl.1999.87.5.1584
- The paper
- Smith, D., Spanel, P., & Davies, S. (1999). Trace gases in breath of healthy volunteers when fasting and after a protein-calorie meal: a preliminary study. Journal of Applied Physiology. https://doi.org/10.1152/jappl.1999.87.5.1584
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.