The DOI matches its Crossref record; 70 of the 70 references it cites were found in a registry or an index.
Selected ion flow tube mass spectrometry (SIFT‐MS) for on‐line trace gas analysis
Abstract
Selected ion flow tube mass spectrometry (SIFT‐MS) is a new analytical technique for the real‐time quantification of several trace gases simultaneously in air and breath. It relies on chemical ionization of the trace gas molecules in air/breath samples introduced into helium carrier gas using H 3 O+, NO+, and O precursor ions. Reactions between the precursor ions and trace gas molecules proceed for an accurately defined time, the precursor and product ions being detected and counted by a downstream mass spectrometer, thus effecting quantification. Absolute concentrations of trace gases in single breath exhalation can be determined by SIFT‐MS down to ppb levels, obviating sample collection and calibration. Illustrative examples of SIFT‐MS studies include (i) analysis of gases from combustion engines, animals and their waste, and food; (ii) breath and urinary headspace studies of metabolites, ethanol metabolism, elevated acetone during ovulation, and exogenous compounds; and (iii) urinary infection and the presence of tumors, the influence of dialysis on breath ammonia, acetone, and isoprene, and acetaldehyde released by cancer cells in vitro. Flowing afterglow mass spectrometry (FA‐MS) is briefly described, which allows on‐line quantification of deuterium in breath water vapor. © 2004 Wiley Periodicals, Inc., Mass Spec Rev 24:661–700, 2005
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
CRC Handbook of Chemistry and Physics
P, D. (1992) · Journal of Molecular Structure · doi:10.1016/0022-2860(92)85083-s · Cited by 9,329
Evaluated Gas Phase Basicities and Proton Affinities of Molecules: An Update
Hunter, E. P. L., & Lias, S. G. (1998) · Journal of Physical and Chemical Reference Data · doi:10.1063/1.556018 · Cited by 2,702
Lindinger, W., Hansel, A., & Jordan, A. (1998) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/s0168-1176(97)00281-4 · Cited by 1,615
Increased nitric oxide in exhaled air of asthmatic patients
Kharitonov, S. A., Yates, D., Robbins, R. A., Barnes, P. J., Logan-Sinclair, R., & Shinebourne, E. A. (1994) · The Lancet · doi:10.1016/s0140-6736(94)90931-8 · Cited by 1,436
Parametrization of the ion–polar molecule collision rate constant by trajectory calculations
Su, T., & Chesnavich, W. J. (1982) · The Journal of Chemical Physics · doi:10.1063/1.442828 · Cited by 1,403
Transport properties of gaseous ions over a wide energy range
Ellis, H. W., Pai, R. Y., McDaniel, E. W., Mason, E. A., & Viehland, L. A. (1976) · Atomic Data and Nuclear Data Tables · doi:10.1016/0092-640x(76)90001-2 · Cited by 967
The mobility and diffusion of ions in gases
McDaniel, E. W., & Mason, E. A. (1973) · CERN Document Server (European Organization for Nuclear Research) · Cited by 942
Volatile organic compounds in breath as markers of lung cancer: a cross-sectional study
Phillips, M., Gleeson, K., Hughes, J. M. B., Greenberg, J., Cataneo, R. N., Baker, L., & McVay, W. P. (1999) · The Lancet · doi:10.1016/s0140-6736(98)07552-7 · Cited by 918
Proton transfer reaction mass spectrometry: on-line trace gas analysis at the ppb level
Hansel, A., Jordan, A., Holzinger, R., Prazeller, P., Vogel, W., & Lindinger, W. (1995) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/0168-1176(95)04294-u · Cited by 727
Gas-Phase Ion and Neutral Thermochemistry
Dobbins, R. A., Mohammed, K., & Sullivan, D. A. (1988) · Cited by 690
Cited by
Advanced methods of plant disease detection. A review
Martinelli, F., Scalenghe, R., Davino, S., Panno, S., Scuderi, G., Ruisi, P., Villa, P., Stroppiana, D., Boschetti, M., Goulart, L. R., et al. (2015) · Agronomy for Sustainable Development · doi:10.1007/s13593-014-0246-1 · Cited by 964
Proton-Transfer Reaction Mass Spectrometry
Blake, R. S., Monks, P. S., & Ellis, A. M. (2009) · Chemical Reviews · doi:10.1021/cr800364q · Cited by 745
Righettoni, M., Tricoli, A., & Pratsinis, S. E. (2010) · Analytical Chemistry · doi:10.1021/ac902695n · Cited by 630
Shin, J., Choi, S., Lee, I., Youn, D., Park, C. O., Lee, J., Tuller, H. L., & Kim, I. (2013) · Advanced Functional Materials · doi:10.1002/adfm.201202729 · Cited by 391
Turner, C., Španěl, P., & Smith, D. (2006) · Physiological Measurement · doi:10.1088/0967-3334/27/4/001 · Cited by 379
Self-citation
Metadata
- Authors
- Smith, D., & Španěl, P.
- Venue
- Mass Spectrometry Reviews
- Publisher
- Wiley
- Published
- 2004-10-19
- Volume
- 24
- Issue
- 5
- Pages
- 661-700
- ISSN
- 0277-7037 (ISSN-L)
- 1098-2787
- OpenAlex
- W2092538532
- Cited by
- 801
- References
- 70
- FWCI
- 7.42
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Selected ion flow tube mass spectrometry (SIFT‐MS) for on‐line trace gas analysis. https://app.cochat.ai/papers/10.1002/mas.20033
- The paper
- Smith, D., & Španěl, P. (2005). Selected ion flow tube mass spectrometry (SIFT‐MS) for on‐line trace gas analysis. Mass Spectrometry Reviews. https://doi.org/10.1002/mas.20033
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.