Cardiac output during exercise by the open circuit acetylene washin method: comparison with direct Fick
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
An open-circuit (OpCirc) acetylene uptake cardiac output (Q˙t) method was modified for use during exercise. Two computational techniques were used. OpCirc1 was based on the integrated uptake vs. end-tidal change in acetylene, and OpCirc2 was based on an iterative finite difference modeling method. Six subjects [28–44 yr, peak oxygen consumption (V˙o 2) = 120% predicted] performed cycle ergometry exercise to compareQ˙t using OpCirc and direct Fick methods. An incremental protocol was repeated twice, separated by a 10-min rest, and subsequently subjects exercised at 85–90% of their peak work rate. Coefficient of variation of the OpCirc methods and Fick were highest at rest (OpCirc1, 7%, OpCirc2, 12%, Fick, 10%) but were lower at moderate to high exercise intensities (OpCirc1, 3%, OpCirc2, 3%, Fick, 5%). OpCirc1 and OpCirc2 Q˙t correlated highly with Fick Q˙t( R 2= 0.90 and 0.89, respectively). There were minimal differences between OpCirc1 and OpCirc2 compared with Fick up to moderate-intensity exercise (<70% peakV˙o 2); however, both techniques tended to underestimate Fick at >70% peakV˙o 2. These differences became significant for OpCirc1 only. Part of the differences between Fick and OpCirc methods at the higher exercise intensities are likely related to inhomogeneities in ventilation and perfusion matching ( R 2= 0.36 for Fick − OpCirc1 vs. alveolar-to-arterial oxygen tension difference). In conclusion, both OpCirc methods provided reproducible, reliable measurements ofQ˙t during mild to moderate exercise. However, only OpCirc2 appeared to approximate FickQ˙t at the higher work intensities.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Influence of age and gender on cardiac output-V˙o2relationships during submaximal cycle ergometry
Proctor, D. N., Beck, K. C., Shen, P. H., Eickhoff, T. J., Halliwill, J. R., & Joyner, M. J. (1998) · Journal of Applied Physiology · doi:10.1152/jappl.1998.84.2.599 · Cited by 135
Self-citation
Cited by
Heat acclimation improves exercise performance
Lorenzo, S., Halliwill, J. R., Sawka, M. N., & Minson, C. T. (2010) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00495.2010 · Cited by 425
Hart, E. C., Charkoudian, N., Wallin, B. G., Curry, T. B., Eisenach, J. H., & Joyner, M. J. (2009) · Hypertension · doi:10.1161/hypertensionaha.108.126391 · Cited by 349
Self-citationRun Sprint Interval Training Improves Aerobic Performance but Not Maximal Cardiac Output
MACPHERSON, R. E. K., HAZELL, T. J., OLVER, T. D., PATERSON, D. H., & LEMON, P. W. R. (2011) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3181e5eacd · Cited by 274
Charkoudian, N., Joyner, M. J., Johnson, C. P., Eisenach, J. H., Dietz, N. M., & Wallin, B. G. (2005) · The Journal of Physiology · doi:10.1113/jphysiol.2005.090076 · Cited by 254
“CO was measured using the open-circuit acetylene uptake technique, as previously described (Johnson et al. 2000).”
MethodSelf-citationSex differences in cardiovascular function during submaximal exercise in humans
Wheatley, C. M., Snyder, E. M., Johnson, B. D., & Olson, T. P. (2014) · SpringerPlus · doi:10.1186/2193-1801-3-445 · Cited by 179
“Arterial oxygen content (CaO2) was calculated using the following equation: CaO2 ¼ 1:34 Hgb SaO2ð Þ þ PaO2 0:0031ð Þ Systemic oxygen transport (SOT) was calculated as CaO2 multiplied by Q. Arterial-venous oxygen (AVO2) difference was calculated according to the Fick equation: AVO2Difference ¼ Q=VO2ð Þ =10 Calculation…”
MethodInfluentialSelf-citation
Metadata
- Authors
- Johnson, B. D., Beck, K. C., Proctor, D. N., Miller, J., Dietz, N. M., & Joyner, M. J.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 2000-05-01
- Volume
- 88
- Issue
- 5
- Pages
- 1650-1658
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W1900518761
- Cited by
- 142
- References
- 1
- FWCI
- 4.18
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.