The DOI matches its Crossref record.
Regional blood flow during exercise in humans measured by near-infrared spectroscopy and indocyanine green
Abstract
Using near-infrared spectroscopy (NIRS) and the tracer indocyanine green (ICG), we quantified blood flow in calf muscle and around the Achilles tendon during plantar flexion (1–9 W). For comparison, blood flow in calf muscle was determined by dye dilution in combination with magnetic resonance imaging measures of muscle volume, and, for the peritendon region, blood flow was measured by 133 Xe washout. From rest to a peak load of 9 W, NIRS-ICG blood flow in calf muscle increased from 2.4 ± 0.2 to 74 ± 5 ml · 100 ml tissue−1 · min−1, similar to that measured by reverse dye (77 ± 6 ml · 100 ml tissue−1 · min−1). Achilles peritendon blood flow measured by NIRS-ICG rose with exercise from 2.2 ± 0.5 to 15.1 ± 0.2 ml · 100 ml−1 · min−1, which was similar to that determined by 133 Xe washout (2.0 ± 0.6 to 14.6 ± 0.3 ml · 100 ml tissue−1 · min−1). This is the first study using NIRS and ICG to quantify regional tissue blood flow during exercise in humans. Due to its high spatial and temporal resolution, the technique may be useful for determining regional blood flow distribution and regulation during exercise in humans.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Role of Extracellular Matrix in Adaptation of Tendon and Skeletal Muscle to Mechanical Loading
KJÆR, M. (2004) · Physiological Reviews · doi:10.1152/physrev.00031.2003 · Cited by 1,586
Self-citationPrinciples, Techniques, and Limitations of Near Infrared Spectroscopy
Ferrari, M., Mottola, L., & Quaresima, V. (2004) · Canadian Journal of Applied Physiology · doi:10.1139/h04-031 · Cited by 997
Progress of near-infrared spectroscopy and topography for brain and muscle clinical applications
Ferrari, M. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2804899 · Cited by 600
The cerebral effects of ascent to high altitudes
Wilson, M. H., Newman, S., & Imray, C. H. (2009) · The Lancet Neurology · doi:10.1016/s1474-4422(09)70014-6 · Cited by 525
Assessment of burn depth and burn wound healing potential
Monstrey, S., Hoeksema, H., Verbelen, J., Pirayesh, A., & Blondeel, P. (2008) · Burns · doi:10.1016/j.burns.2008.01.009 · Cited by 471
Near-Infrared Spectroscopy in Bio-Applications
Beć, K. B., Grabska, J., & Huck, C. W. (2020) · Molecules · doi:10.3390/molecules25122948 · Cited by 471
Grassi, B., & Quaresima, V. (2016) · Journal of Biomedical Optics · doi:10.1117/1.jbo.21.9.091313 · Cited by 345
Near‐infrared spectroscopy for monitoring muscle oxygenation
Boushel, R., & Piantadosi, C. A. (2000) · Acta Physiologica Scandinavica · doi:10.1046/j.1365-201x.2000.00713.x · Cited by 299
Self-citationSouthern, W. M., Ryan, T. E., Reynolds, M. A., & McCully, K. (2014) · Applied Physiology, Nutrition, and Metabolism · doi:10.1139/apnm-2013-0347 · Cited by 80
“2007) and 133Xe washout (Boushel et al. 2000).”
Quaresima, V., Ferrari, M., Franceschini, M. A., Hoimes, M. L., & Fantini, S. (2004) · Journal of Biomedical Optics · doi:10.1117/1.1646417 · Cited by 45
Louvaris, Z., Zakynthinos, S., Aliverti, A., Habazettl, H., Vasilopoulou, M., Andrianopoulos, V., Wagner, H., Wagner, P., & Vogiatzis, I. (2012) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00481.2012 · Cited by 45
Metadata
- Authors
- Boushel, R., Langberg, H., Olesen, J., Nowak, M., Simonsen, L., Bülow, J., & Kjær, M.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 2000-11-01
- Volume
- 89
- Issue
- 5
- Pages
- 1868-1878
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2127722218
- Cited by
- 163
- References
- 0
- FWCI
- 11.83
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.