CoChat

Spatial distribution of vastus lateralis blood flow and oxyhemoglobin saturation measured at the end of isometric quadriceps contraction by multichannel near-infrared spectroscopy

Open access

The DOI matches its Crossref record; 38 of the 38 references it cites were found in a registry or an index.

Abstract

Muscle blood flow (MBF) and muscle oxygen saturation (SmO2) were measured at eight locations (four proximal, four distal) over a 4×8 cm2 area of the vastus lateralis at rest and immediately after isometric, maximal quadriceps contraction using multichannel, frequency-domain, near-infrared spectroscopy. A venous occlusion was applied 20 s before the end of the exercise, so that the venous-occlusion-induced increase in total hemoglobin was recorded without any delay after the end of the exercise. Therefore, we were able to investigate the relationship between the exercise-induced changes in vastus lateralis MBF and SmO2. After exercise, MBF increased significantly at each measured location. Comparing the MBF values measured at the end of exercise in the proximal and distal regions, we observed that only one proximal region had a significantly higher MBF than the corresponding distal one. The maximum desaturation measured during exercise was positively correlated with the postexercise to pre-exercise MBF ratio in both the proximal (P = 0.016) and distal (P = 0.0065) regions. These data confirm that frequency-domain tissue oximeters are noninvasive, powerful tools to investigate the spatial and temporal features of muscle blood flow and oxygenation, with potential applications in areas of pathophysiology.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1117/1.1646417

Cites

38 of 38 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 38 references

Research works printed but not linked: 1

  1. van Beekvelt, 2001, J. Appl. Physiol., 90, 511, 10.1152/jappl.2001.90.2.511 · DOI · Paper page

Cited by

See all 45

Metadata

Authors
Quaresima, V., Ferrari, M., Franceschini, M. A., Hoimes, M. L., & Fantini, S.
Affiliations
  • University of L'Aquila (IT)
  • Tufts University (US)
Venue
Journal of Biomedical Optics
Published
2004-03-01
Volume
9
Issue
02
Pages
413-420
ISSN
  • 1083-3668 (ISSN-L)
  • 1560-2281
OpenAlex
W2102663326
Cited by
45
References
38
Citations by year
2026: 2 · 2023: 2 · 2021: 1 · 2020: 2 · 2019: 2 · 2018: 1 · 2017: 2 · 2016: 1 · 2014: 3 · 2013: 1 · 2012: 3
FWCI
2.79
Type
journal article
Language
en
Open access
Locations
  • Journal of Biomedical Optics (publishedVersion)
  • PubMed (publishedVersion)
  • Archivio Istituzionale della Ricerca - Università degli Studi dell Aquila (submittedVersion)
  • INFM-OAR (INFN Catania) (submittedVersion, other-oa)
Funders
  • National Science Foundation
  • National Institutes of Health
  • National Institute of Mental Health (R01-MH62854, R01MH062854)
  • National Institute of Biomedical Imaging and Bioengineering (R01EB001954)
  • Eunice Kennedy Shriver National Institute of Child Health and Human Development (R01HD042908, R01 HD42908)
Topics
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Optical Imaging and Spectroscopy Techniques
  • Health Sciences › Medicine › Physiology (medical) › Cardiovascular and exercise physiology
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Infrared Thermography in Medicine
Keywords
vastus lateralis, muscle blood flow, muscle oxygen saturation, venous occlusion, spatial distribution, muscle oxygenation, exercise-induced desaturation, frequency-domain near-infrared spectroscopy, tissue oximetry
MeSH terms
Adult, Hip, Humans, Isometric Contraction, Oxyhemoglobins, Regional Blood Flow, Thigh, Muscle, Skeletal, Spectroscopy, Near-Infrared

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Spatial distribution of vastus lateralis blood flow and oxyhemoglobin saturation measured at the end of isometric quadriceps contraction by multichannel near-infrared spectroscopy. https://app.cochat.ai/papers/10.1117/1.1646417
The paper
Quaresima, V., Ferrari, M., Franceschini, M. A., Hoimes, M. L., & Fantini, S. (2004). Spatial distribution of vastus lateralis blood flow and oxyhemoglobin saturation measured at the end of isometric quadriceps contraction by multichannel near-infrared spectroscopy. Journal of Biomedical Optics. https://doi.org/10.1117/1.1646417

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.